over operating free-air temperature range (unless otherwise noted) (1) | MIN | MAX | UNIT |
|---|
| Input voltage range(2) | EN | –0.3 | 7.7 | V |
| SW | DC | –3 | 30 |
| Transient < 10ns | –5 | 32 |
| VBST | –0.3 | 36 |
| VBST(3) | –0.3 | 6 |
| VBST when transient < 10ns | | 38 |
| VDD | –0.3 | 28 |
| VIN | –0.3 | 30 |
| VIN-SW DC |
-3 |
30 |
| VIN-SW < 10ns
transient |
-5 |
32 |
| VO, FB, MODE, RF | –0.3 | 6 |
| Output voltage range | PGOOD | –0.3 | 7.7 | V |
| VREG, TRIP | –0.3 | 6 |
| Junction temperature, TJ | –40 | 150 | °C |
| Storage temperature, Tstg | –55 | 150 | °C |
(1) Stresses beyond those listed under
Absolute Maximum Ratings may cause
permanent damage to the device. These are stress ratings only, which do not
imply functional operation of the device at these or any other conditions beyond
those indicated under
Recommnded Oeprating Conditions. Exposure to
absolute-maximum-rated conditions for extended periods may affect device
reliability.
(2) All voltages are with respect to network ground terminal.
(3) Voltage values are with respect to the SW terminal.