SLUUBH5A November 2016 – February 2022 TPS546C23
Table 2-1 lists the electrical performance specifications under room temperature 25°C.
| Parameter | Test Conditions | MIN | TYP | MAX | Unit |
|---|---|---|---|---|---|
| Input Characteristics | |||||
| Voltage range | VIN | 5 | 12 | 18 | V |
| Maximum input current | VIN = 12 V, IO = 70 A | 8.5 | A | ||
| No load input current | VIN = 12 V, IO = 0 A | 120 | mA | ||
| Output Characteristics | |||||
| Output voltage, VOUT | 1.2 | V | |||
| Output load current, IOUT(1) | 0 | 70 | A | ||
| Output voltage regulation | Line regulation: input voltage = 5 V to 18 V | 1% | |||
| Load regulation: output current = 0 A to 70 A | 1% | ||||
| Output voltage ripple, VOUT | VIN = 12 V, IOUT = 70 A | 10 | mVpp | ||
| Output overcurrent protection threshold | Load current IOUT1, default setting of U1 | 42 | A | ||
| Load current IOUT2, default setting of U2 | 42 | A | |||
| Systems Characteristics | |||||
| Switching frequency | VIN = 12 V | 500 | kHz | ||
| Full load efficiency, VOUT(2) | VIN = 12 V, IOUT = 70 A | 86% | |||
| Operating temperature | Tambient | 25 | °C | ||
| PMBUS Interface and Pin-Strapping | |||||
| U1 PMBUS address | Programmed by R33 and R35 | 27 | Decimal | ||
| U2 PMBus address | Programmed by R37 and R36 | 36 | |||
| U1 voltage reference | Default setting of VOUT_COMMAND | 600 | mV | ||
| U2 voltage reference | Default setting of VOUT_COMMAND | 600 | |||
| U1 soft-start time (TON_RISE) | Default setting of TON_RISE | 3 | ms | ||
| U2 soft-start time (TON_RISE) | Default setting of TON_RISE | 3 | |||