SLUUCH1 June   2021 TPS62933

 

  1. 1TPS62933EVM-129 3-A, Regulator Evaluation Module
    1.     Trademarks
  2. 1Introduction
  3. 2Performance Specification Summary
  4. 3Modifications
    1. 3.1 Output Voltage Setpoint
  5. 4Test Setup and Results
    1. 4.1 Input/Output Connections
    2. 4.2 Start-Up Procedure
    3. 4.3 Load Transient Response
    4. 4.4 Output Voltage Ripple
    5. 4.5 Start-Up
    6. 4.6 Shut-Down
  6. 5Board Layout
    1. 5.1 Layout
  7. 6Schematic, List of Materials, and Reference
    1. 6.1 Schematic
    2. 6.2 List of Materials

Start-Up Procedure

  1. Ensure that the jumper at JP3 (Enable control) pins 2 and 3 are covered to shunt EN to GND, disabling the output.
  2. Apply appropriate VIN voltage to VIN (J2-1) and GND (J2-2).
  3. Move the jumper at JP3 (Enable control) pins 2 and 3 (EN and GND) to enable the output.