SLUUCX5 september 2023
Figure 4-30 to Figure 4-33 show output voltage VOUT deviation when load current step change is between 0 and 100%, at 100-Hz rate.
Blue = VOUT, Green = Load Current.
Figure 3-30 Load Transient Response at VOUT = 20 V Overshoot / Undershoot = 357 mV / -619 mV
Figure 3-31 Transient Response at VOUT = 15 V Overshoot / Undershoot = 366 mV / -562 mV
Figure 3-32 Transient Response at VOUT = 9 V Overshoot / Undershoot = 326 mV / -426 mV
Figure 3-33 Transient Response at VOUT = 5 V Overshoot / Undershoot = 326 mV / -426 mV