SLVK232 February   2026 TPS7H4104-SP

 

  1.   1
  2.   2
  3.   Trademarks
  4. 1 Introduction
  5. 2 Single-Event Effects (SEE)
  6. 3 Device and Test Board Information
  7. 4 Irradiation Facility and Setup
  8. 5 Depth, Range, and LETEFF Calculation
  9. 6 Test Setup and Procedures
  10. 7 Destructive Single-Event Effects (DSEE)
    1. 7.1 Safe Operating Area (SOA) Results
    2. 7.2 Single-Event Latch-up (SEL) Results
    3. 7.3 Single-Event Burnout (SEB) and Single-Event Gate Rupture (SEGR) Results
  11. 8 Single-Event Transients (SET)
  12. 9 Event Rate Calculations
  13. 10Summary
  14.   A References

Single-Event Burnout (SEB) and Single-Event Gate Rupture (SEGR) Results

During the SEB/SEGR characterization, the device was tested at room temperature (approximately 25°C). The device was tested under both the enabled and disabled mode. For the SEB-OFF mode the device was disabled using each channel's EN-pin by forcing 0V (using CH # 1/3 of a E36311A Keysight PS).

The species used for the SEB testing was 169Tm (KSEE) at 19.5 MeV/nucleon. An angle of incidence of 0° was used to achieve a LETEFF of ≈ 75 MeV·cm2/mg (for more details refer to Section 5). The kinetic energy in the vacuum for 169Tm is 3.295 GeV. Flux of ≈ 105 ions/cm2/s and a fluence of ≈107 ions/cm2 per run was used. Run duration to achieve this fluence was ≈2 minutes. The 4 devices were powered up for SEB at the maximum recommended operating conditions based on the SOA, which are a VIN of 6.5V and 3A/channel in the high current case and a VIN of 7V and 1.5A/channel in the high voltage case. Output conditions were tested in two different configurations, either with each channel configured to output 1.2V or 1.8V. During testing of the 4 devices, the TPS7H4104-SP did not exhibit any SEB with heavy-ions with LETEFF = 75 MeV·cm2/mg at flux ≈105 ions/cm2/s , fluence of ≈107 ions/cm2, and a die temperature of 25°C while maintaining operating conditions within the SOA. Table 8-9 shows the SEB/SEGR test conditions and results.

Table 7-7 Summary of TPS7H4104-SP SEB/SEGR Test Condition and Results
RUN #UNIT #FacilityIONLETEFF (MeV·cm2/mg)FLUX (ions/cm2/s)FLUENCE (ions/cm2)ENABLED STATUS

VIN (V)

VOUT (V)

IOUT/Channel (A)

SEB EVENT?

5

1

KSEE

169Tm

75

1.82 × 105

1.00 × 107

EN

7

1.2

1.5

No

6

1

KSEE169Tm

75

1.56 × 105

1.00 × 107DIS

7

0

0

No

7

2

KSEE169Tm

75

9.44 × 104

1.00 × 107

EN

7

1.8

1.5

No

8

2

KSEE169Tm

75

9.86 × 104

1.00 × 107

DIS

7

0

0

No

9

3

KSEE169Tm

75

1.07 × 105

1.00 × 107

EN

6.5

1.2

3

No

10

3

KSEE169Tm

75

1.01 × 105

1.00 × 107

DIS

7

0

0

No

11

4

KSEE169Tm

75

1.06 × 105

1.00 × 107

EN

6.5

1.8

3

No

12

4

KSEE169Tm

75

1.04 × 105

1.00 × 107

DIS

7

0

0

No

Using the MFTF method described in Single-Event Effects (SEE) Confidence Interval Calculations application report, the upper-bound cross-section (using a 95% confidence level) is calculated as:

σSEB ≤ 4.61 x 10-8 cm2/device for LETEFF = 75 MeV·cm2/mg and T = 25°C.

 SEB On Run #7 (VIN
                    = 7V, VOUT = 1.8V, IOUT = 1.5A/ch) Figure 7-5 SEB On Run #7 (VIN = 7V, VOUT = 1.8V, IOUT = 1.5A/ch)
 SEB Off Run #8 (VIN = 7V)Figure 7-6 SEB Off Run #8 (VIN = 7V)
 SEB On Run #9 (VIN = 6.5V, VOUT = 1.2V, IOUT
                    = 3A/ch) Figure 7-7 SEB On Run #9 (VIN = 6.5V, VOUT = 1.2V, IOUT = 3A/ch)