SLVSDE4F March 2017 – January 2026 TPS61253A , TPS61253E , TPS61253F
PRODUCTION DATA
During the start-up phase, the output current is limited to the pre-charge current limit which is specified as the ILIM_DC in Section 6.5.
The TPS61253x employs a valley current sensing scheme during the normal boost switching phase. When the output load increases, the cycle-by-cycle valley current limit will be triggered. As shown in Figure 7-1, the maximum continuous output current before entering the current limit operation can be defined by Equation 1:



where
Figure 7-1 Current Limit OperationIf the output current is further increased and triggers the short protection threshold (typical 6A of inductor current), the TPS61253x enters hiccup mode. Once the hiccup is triggered, the device turns on the high-side FET for around 1ms with the pre-charge current limit and stops for around 20ms. The hiccup on / off cycle repeats again and again if the short condition is present. Figure 7-2 illustrates the TPS61253x working scheme of the hiccup mode. The average current and thermal will be much lowered at the hiccup steady state and the device can recover automatically as long as the short releases.
Figure 7-2 Hiccup Mode Short Protection