SLVSFW1 December   2025 TPS1HC120-Q1

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Device Comparison Table
  6. Pin Configuration and Functions
  7. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Switching Characteristics
    7. 6.7 Typical Characteristics
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 ORing of EN and EN_AUX
      2. 7.3.2 Inductive-Load Switching-Off Clamp
      3. 7.3.3 Full Protections and Diagnostics
        1. 7.3.3.1  Programmable Current Limit
        2. 7.3.3.2  Short-Circuit and Overload Protection
          1. 7.3.3.2.1 Capacitive Charging
        3. 7.3.3.3  On-state Open-Load Detection
        4. 7.3.3.4  Reverse-Polarity and Reverse Battery Protection
        5. 7.3.3.5  Thermal Protection Behavior
        6. 7.3.3.6  UVLO Protection
        7. 7.3.3.7  Loss of GND Protection
        8. 7.3.3.8  Loss of Power Supply Protection
        9. 7.3.3.9  Reverse Current Protection
        10. 7.3.3.10 Protection for MCU I/Os
    4. 7.4 Device Functional Modes
      1. 7.4.1 Working Mode
  9. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Detailed Design Procedure
        1. 8.2.1.1 Dynamically Changing Current Limit
        2. 8.2.1.2 AEC Q100-012 Test Grade A Certification
        3. 8.2.1.3 EMC Transient Disturbances Test
      2. 8.2.2 Power Dissipation Calculation
      3. 8.2.3 Application Curves
    3. 8.3 Power Supply Recommendations
    4. 8.4 Layout
      1. 8.4.1 Layout Guidelines
      2. 8.4.2 Layout Examples
        1. 8.4.2.1 Without a GND Network
        2. 8.4.2.2 With a GND Network
  10. Device and Documentation Support
    1. 9.1 Third-Party Products Disclaimer
    2. 9.2 Receiving Notification of Documentation Updates
    3. 9.3 Support Resources
    4. 9.4 Trademarks
    5. 9.5 Electrostatic Discharge Caution
    6. 9.6 Glossary
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

Power Supply Recommendations

The device is qualified for both automotive and industrial applications. The normal power supply connection is a 12V automotive system. The supply voltage should be within the range specified in the Recommended Operating Conditions.

Table 8-6 Voltage Operating Ranges
VBB VOLTAGE RANGE NOTE
3V to 6V

Extended lower 12V automotive battery operation such as cold crank and start-stop. Device is fully functional and protected but some parametrics such as RON, current limit accuracy and timing parameters can deviate from specifications. Check the individual specifications in Electrical Characteristics to confirm the voltage range it is applicable for.

6V to 18V

Nominal 12V automotive battery voltage range. All parametric specifications apply and the device is fully functional and protected.

18V to 24V

Extended upper 12V automotive battery operation such as double battery. Device is fully functional and protected but some parametrics such as RON, current limit accuracy, and timing parameters can deviate from specifications. Check the individual specifications in Electrical Characteristics to confirm the voltage range it is applicable for.

35V

Load dump voltage. Device is operational and lets the pulse pass through without being damaged but does not protect against short circuits.