The thermal protection behavior can be split up
into two categories of events that can occur. Figure 8-16 shows each of these categories.
- Relative thermal shutdown: The device is enabled
into an overcurrent event. The DIAG_EN pin is high so that diagnostics can be
monitored on SNS and FLT. The output current rises up to the IILIM
level and the FLT goes low while the SNS goes to VSNSFH. With this
large amount of current going through the junction temperature of the FET
increases rapidly with respect to the controller temperature. When the power FET
temperature rises TREL amount above the controller junction
temperature ΔT = TFET – TCON > TREL, the
device shuts down. The faults are continually shown on SNS and FLT and the part
waits for the tRETRY timer to expire. When tRETRY timer expires,
since EN is still high, the device comes back on into this IILIM
condition.
- Absolute thermal shutdown: In this case, the
ambient temperature is now much higher than previous. The device is still
enabled in an overcurrent event with DIAG_EN high. However, in this case the
junction temperature rises up and hits an absolute reference temperature, TABS,
and then shuts down. The device does not recover until both TJ <
TABS – Thys and the tRETRY timer
expires.