SLVSI25 July 2025 TPS546B25
PRODUCTION DATA
| CMD Address | 9Ah |
| Write Transaction: | Block Write |
| Read Transaction: | Block Read |
| Format: | Unsigned Binary (2 bytes) |
| NVM Backup: | Yes |
This Read-only Block Read command returns 2 bytes (16 bits) with the manufacturer’s model number. The BYTE_COUNT field in the Block Read command will be 04h (indicating 2 bytes will follow).
Return to Supported PMBus Commands.
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
| R/W | R/W | R/W | R/W | R/W | R/W | R/W | R/W |
| MFR model third digit | MFR model fourth digit | ||||||
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| R/W | R/W | R/W | R/W | R/W | R/W | R/W | R/W |
| MFR model first digit | MFR model second digit | ||||||
| LEGEND: R/W = Read/Write; R = Read only |