SLVSI27
December 2025
TPS1HC08-Q1
PRODUCTION DATA
1
1
Features
2
Applications
3
Description
4
Device Comparison Table
5
Pin Configuration and Functions
6
Specifications
6.1
Absolute Maximum Ratings
6.2
ESD Ratings
6.3
Recommended Operating Conditions
6.4
Thermal Information
6.5
Electrical Characteristics
6.6
SNS Timing Characteristics
6.7
Switching Characteristics
6.8
Typical Characteristics
7
Parameter Measurement Information
8
Detailed Description
8.1
Overview
8.2
Functional Block Diagram
8.3
Feature Description
8.3.1
Input Voltage Thresholds
8.3.2
Accurate Current Sense
8.3.2.1
SNS Response Time
8.3.2.2
SNS Output Filter
8.3.2.3
Multiplexing of Current Sense Across Devices
8.3.3
Overcurrent Protection
8.3.3.1
Adjustable Current Limit
8.3.3.1.1
Current Limiting With Thermal Regulation
8.3.3.1.2
Current Limiting With No Thermal Regulation
8.3.3.1.3
Current Limit Foldback
8.3.3.1.4
Current Limit Accuracy
8.3.3.2
Thermal Shutdown
8.3.3.2.1
Relative Thermal Shutdown
8.3.3.2.2
Absolute Thermal Shutdown
8.3.4
Retry Protection Mechanism From Thermal Shutdown
8.3.5
Inductive-Load Switching-Off Clamp
8.3.6
Slower Slew Rate Option
8.3.7
Capacitive Load Charging
8.3.7.1
Adjustable Current Limiting for Inrush Control
8.3.7.2
Current Limit with Thermal Regulation for Capacitive Loads
8.3.7.3
Retry Thermal Shutdown Behavior for Capacitive Loads
8.3.7.4
Impact of DC Load on Capacitive Charging Capability
8.3.7.5
Device Capability
8.3.8
Bulb Charging
8.3.8.1
Non-Thermal Regulated Mode for Bulb Loads
8.3.8.2
Thermal Management During Bulb Inrush
8.3.8.3
Device Capability
8.3.9
Fault Detection and Reporting
8.3.9.1
Diagnostic Enable Function
8.3.9.2
FLT Reporting
8.3.9.3
FLT Timings
8.3.9.4
Fault Table
8.3.10
Full Diagnostics
8.3.10.1
Open-Load Detection
8.3.10.1.1
Channel On
8.3.10.1.2
Channel Off
8.3.10.2
Short-to-Battery Detection
8.3.10.3
Reverse-Polarity and Battery Protection
8.3.11
Full Protections
8.3.11.1
UVLO Protection
8.3.11.2
Loss of GND Protection
8.3.11.3
Loss of Power Supply Protection
8.3.11.4
Reverse Current Protection
8.3.11.5
Protection for MCU I/Os
8.4
Device Functional Modes
9
Application and Implementation
9.1
Application Information
9.2
Typical Application
9.2.1
Design Requirements
9.2.2
Detailed Design Procedure
9.2.2.1
EMC Transient Disturbances Test
9.2.3
Transient Thermal Performance
9.2.4
Application Curves
9.3
Power Supply Recommendations
9.4
Layout
9.4.1
Layout Guidelines
9.4.2
Layout Examples
9.4.2.1
Without a GND Network
9.4.2.2
With a GND Network
9.4.3
Wettable Flank Package
10
Revision History
11
Device and Documentation Support
11.1
Third-Party Products Disclaimer
11.2
Receiving Notification of Documentation Updates
11.3
Support Resources
11.4
Trademarks
11.5
Electrostatic Discharge Caution
11.6
Glossary
12
Mechanical, Packaging, and Orderable Information
1
Features
Single-Channel
smart high-side switch with full diagnostics
Control using GPIO pins
Open-drain status output
Current sense analog output: sense accuracy <
±5% at ≥ 2A
Wide operating voltage: 3V to 28V
Low R
ON
:
9.8mΩ
typical,
16.5mΩ
max at 150°C
Ultra-low standby current: <1.4μA at 85°C
Adjustable current limit with and without thermal regulation
Current limit range:
10A
to
25A
Protection
Overload and short-circuit protection
Undervoltage lockout (UVLO)
Thermal shutdown and swing with self recovery
Integrated output clamp to demagnetize inductive loads
Loss-of-GND, loss-of-battery, and reverse battery protection
Diagnostics
Global fault report for fast interrupt
Overcurrent and short-to-ground detection
Open-load and short-to-battery detection
Qualified for automotive applications
AEC-Q100 qualified with the following results:
Temperature grade 1: –40°C to 125°C ambient operating temperature range
Passed electrical transient disturbance immunity tests (ISO7637-2 and ISO16750-2)
Small footprint:
11
-pin wettable flank
VQFN-HR
2.2mm x 3.6mm
,
0.55mm
pitch
Functional Safety Capable
Documentation available to aid functional safety system design