SLVSIP6 June 2026 LMK6L-Q1
ADVMIX
For the best electrical performance of the LMK6L-Q1, TI recommends using 0.1µF and 1µF capacitor on the device power supply bypass network. Place these capacitors as close as possible to the supply pins. TI also recommends using component side mounting of the power supply bypass capacitors and use 0201 body size for the 0.1µF capacitor and 0603 body size for the 1µF capacitor to facilitate signal routing. Keep the connections between the bypass capacitors and the power supply on the device as short as possible. Ground the other side of the capacitor using a low impedance connection to the ground plane.