  6. 5 Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 ESD Ratings
    3. 5.3 Recommended Operating Conditions
    4. 5.4 Thermal Information
    5. 5.5 Electrical Characteristics
    6. 5.6 I2C Timing Requirements
    7. 5.7 Typical Characteristics
  7. 6 Detailed Description
    1. 6.1 Overview
    2. 6.2 Functional Block Diagram
    3. 6.3 Feature Description
      1. 6.3.1  VCC Power Supply
      2. 6.3.2  Default Output Enable (OE) Bit Status
      3. 6.3.3  Input Undervoltage Lockout
      4. 6.3.4  Enable and Programmable UVLO
      5. 6.3.5  Soft Start
      6. 6.3.6  Shutdown and Load Discharge
      7. 6.3.7  Switching Frequency
      8. 6.3.8  Switching Frequency Dithering
      9. 6.3.9  Inductor Current Limit
      10. 6.3.10 Internal Charge Path
      11. 6.3.11 Output Voltage Setting
      12. 6.3.12 Output Current Limit
      13. 6.3.13 Output Cable Voltage Drop Compensation
      14. 6.3.14 Input Overvoltage Protection
      15. 6.3.15 Output Overvoltage Protection
      16. 6.3.16 Output Short-Circuit Protection
      17. 6.3.17 Thermal Shutdown
    4. 6.4 Device Functional Modes
      1. 6.4.1 PWM Mode
      2. 6.4.2 Power Save Mode
    5. 6.5 Programming
      1. 6.5.1 Data Validity
      2. 6.5.2 START and STOP Conditions
      3. 6.5.3 Byte Format
      4. 6.5.4 Acknowledge (ACK) and Not Acknowledge (NACK)
      5. 6.5.5 Target Address and Data Direction Bit
      6. 6.5.6 Single Read and Write
      7. 6.5.7 Multi-Read and Multi-Write
  8. 7 Register Maps
    1. 7.1 REF Register (Address = 0h, 1h) [reset = 10100100b, 00000001b]
    2. 7.2 IOUT_LIMIT Register (Address = 2h) [reset = 11100100b]
    3. 7.3 VOUT_SR Register (Address = 3h) [reset = 00000001b]
    4. 7.4 VOUT_FS Register (Address = 4h) [reset = 00000011b]
    5. 7.5 CDC Register (Address = 5h) [reset = 11110000b]
    6. 7.6 MODE Register (Address = 6h) [reset = 00100000b]
    7. 7.7 STATUS Register (Address = 7h) [reset = 00000001b]
    8. 7.8 Register Summary
  9. 8 Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
        1. 8.2.2.1 Switching Frequency
        2. 8.2.2.2 Output Voltage Setting
        3. 8.2.2.3 Inductor Selection
        4. 8.2.2.4 Input Capacitor
        5. 8.2.2.5 Output Capacitor
        6. 8.2.2.6 Output Current Limit
        7. 8.2.2.7 Loop Stability
      3. 8.2.3 Application Curves
    3. 8.3 Power Supply Recommendations
    4. 8.4 Layout
      1. 8.4.1 Layout Guidelines
      2. 8.4.2 Layout Example
  10. 9 Device and Documentation Support
    1. 9.1 Device Support
      1. 9.1.1 Third-Party Products Disclaimer
    2. 9.2 Receiving Notification of Documentation Updates
    3. 9.3 Support Resources
    4. 9.4 Trademarks
    5. 9.5 Electrostatic Discharge Caution
    6. 9.6 Glossary
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information

CDC Register (Address = 5h) [reset = 11110000b]

CDC is shown in Figure 7-6 and described in Table 7-7.

Return to Summary Table.

Register 05h sets masks for SC bit, OCP bit, OVP bit and TSD bit in register 07h. When the mask bit is set and corresponding fault happens, the device masks the fault indication on FB/INT pin

In addition, register 05h sets the voltage rise added to the setting output voltage with respect to the sensed output current.

Figure 7-6 CDC Register
76543210
SC_MASKOCP_MASKOVP_MASKTSD_MASKCDC_OPTIONCDC
R/W-1bR/W-1bR/W-1bR/W-1bR/W-0bR/W-000b
Table 7-7 CDC Register Field Descriptions
BitFieldTypeResetDescription
7SC_MASKR/W1bShort circuit mask

0b = Disabled SC indication

1b = Enable SC indication (Default)

6OCP_MASKR/W1bOver current mask

0b = Disabled OCP indication

1b = Enable OCP indication (Default)

5OVP_MASKR/W1bOvervoltage mask

0b = Disabled OVP indication

1b = Enable OVP indication (Default)

4TSD_MASKR/W1bThermal shutdown mask

0b = Disabled TSD indication

1b = Enable TSD indication (Default)

3CDC_OPTIONR/W0bDisable or enable cable voltage drop compensation function

0b = Disable CDC compensation (Default)

1b = Enable CDC compensation

2-0CDCR/W000bCompensation for voltage drop over the cable

000b = 0V output voltage rise with 5A output current (Default)

001b = 0.1V output voltage rise with 5A output current

010b = 0.2V output voltage rise with 5A output current

011b = 0.3V output voltage rise with 5A output current

100b = 0.4V output voltage rise with 5A output current

101b = 0.5V output voltage rise with 5A output current

110b = 0.6V output voltage rise with 5A output current

111b = 0.7V output voltage rise with 5A output current