SLVSL42C January 2026 – July 2026 OPA2486 , OPA486
PRODMIX
The previous section demonstrated how to design an instrumentation amplifier that provides high impedance inputs, high common-mode rejection, and differential to single ended conversion. As shown previously, the implementation requires the use of at least three channel counts of OPAx486. In many applications, power and space on the board is strictly limited and a smaller, lower power design is desirable. Figure 7-6 demonstrates an alternative configuration to the design discussed in detail in the previous section. This design provides a 33% reduction in quiescent current consumption and can be implemented using a dual channel package for significant size improvement. The trade-off for this power and size improvement is common-mode rejection (ac in particular) and a more limited input common-mode voltage.