  4. Introduction
  5. Choosing a Mechanical Implementation
  6. Choosing a Magnetic Implementation
  7. Magnet Sensor Placement
  8. Prototyping and Bench Testing
  9. Error Sources
  10. Summary
  11. Recommended Devices
  12. References
  13. 10Revision History

Choosing a Mechanical Implementation

The mechanical implementation of the E-shifter not only has influence over the end user’s experience, but also has influence on what magnet-sensor pairings are viable. In Figure 2-1 there are five possible mechanical implementations. From left to right are button, dial, joystick, lever, and paddle implementations. This document examines the lever design. For content relevant to the other implementations, check out Section 9.

 E-Shifter Mechanical
        Implementation Figure 2-1 E-Shifter Mechanical Implementation