SNAS883A June 2024 – May 2025 LMX1860-SEP
PRODUCTION DATA
The four main clocks must be the same frequency, but this frequency can be bypassed, multiplied, or divided. This is determined by the CLK_MUX word.
| CLK_MUX | OPTION | VALUES SUPPORTED | |
|---|---|---|---|
| 0 | Buffer Mode | ÷1 (bypass) | |
| 1 | Divider Mode | ÷2, 3, 4, 5, and 7 | |
| 2 | Multiplier Mode | x2, x3, x4 | |