VALUE |
UNIT |
| V(ESD), Electrostatic discharge(1) |
LM60-Q1 |
Human-body model (HBM), per AEC Q100-002(2) |
±2500 |
V |
| Charged-device model (CDM), per JEDEC specification JESD22-C101(3) |
±1000 |
(1) The human body model is a 100pF capacitor discharged through a 1.5kΩ resistor into each pin. The machine model is a 200pF capacitor discharged directly into each pin.
(2) AEC Q100-002 indicates that HBM stressing shall be in accordance with the ANSI/ESDA/JEDEC JS-001 specification.
(3) JEDEC document JEP157 states that 250V CDM allows safe manufacturing with a standard ESD control process.