SNOSB30Q October 2008 – March 2026 LMH6554
PRODUCTION DATA
As noted previously, capacitive loads must be isolated from the amplifier output with small valued resistors. This is particularly the case when the load has a resistive component that is 500Ω or higher. A typical ADC has capacitive components of around 1pF and the resistive component can be 1000Ω or higher. If driving a transmission line, such as 50Ω coaxial or 100Ω twisted pair, using matching resistors is sufficient to isolate any subsequent capacitance. For other applications, see Figure 7-5 in Section 5.6.