SNOSDI6 October 2026 LMP8640-Q1
PRODUCTION DATA
In this example, a current monitor application is required to measure the current into a load (peak current 10 A) with a resolution of 10 mA and 0.5% of accuracy.
The 10bit analog to digital converter accepts a maximum input voltage of 4.1 V. To not burn too much power on the shunt resistor, the resistor needs to be less than 10 mΩ. Table 8-1 below summarizes the other design conditions.
| WORKING CONDITION | VALUE | |
|---|---|---|
| MIN | MAX | |
| Supply Voltage | 5 V | 5.5 V |
| Common mode Voltage | 48 V | 70 V |
| Temperature | 0°C | 70°C |
| Signal BW | 50 kHz | |