SNVS089P July   2000  – September 2026 LM3488

PRODUCTION DATA  

  1.   1
  2. 1 Features
  3. 2 Applications
  4. 3 Description
  5. 4 Pin Configuration and Functions
  6. 5 Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 ESD Ratings: LM3488
    3. 5.3 Recommended Operating Conditions
    4. 5.4 Thermal Information
    5. 5.5 Electrical Characteristics
    6. 5.6 Typical Characteristics
  7. 6 Detailed Description
    1. 6.1 Overview
    2. 6.2 Functional Block Diagram
    3. 6.3 Feature Description
      1. 6.3.1 Slope Compensation Ramp
      2. 6.3.2 Frequency Adjust, Synchronization, Shutdown
      3. 6.3.3 Short-Circuit Protection
    4. 6.4 Device Functional Modes
  8. 7 Application and Implementation
    1. 7.1 Application Information
    2. 7.2 Typical Applications
      1. 7.2.1 Boost Converter
        1. 7.2.1.1 Design Requirements
        2. 7.2.1.2 Detailed Design Procedure
          1. 7.2.1.2.1 Custom Design With WEBENCH® Tools
          2. 7.2.1.2.2 Power Inductor Selection
          3. 7.2.1.2.3 Programming the Output Voltage
          4. 7.2.1.2.4 Setting the Current Limit
          5. 7.2.1.2.5 Current Limit With External Slope Compensation
          6. 7.2.1.2.6 Power Diode Selection
          7. 7.2.1.2.7 Power MOSFET Selection
          8. 7.2.1.2.8 Input Capacitor Selection
          9. 7.2.1.2.9 Output Capacitor Selection
        3. 7.2.1.3 Application Curve
      2. 7.2.2 Designing SEPIC Using LM3488
        1. 7.2.2.1 Design Requirements
        2. 7.2.2.2 Detailed Design Procedure
          1. 7.2.2.2.1 Power MOSFET Selection
          2. 7.2.2.2.2 Power Diode Selection
          3. 7.2.2.2.3 Selection Of Inductors L1 and L2
          4. 7.2.2.2.4 Sense Resistor Selection
          5. 7.2.2.2.5 SEPIC Capacitor Selection
          6. 7.2.2.2.6 Input Capacitor Selection
          7. 7.2.2.2.7 Output Capacitor Selection
    3. 7.3 Power Supply Recommendations
    4. 7.4 Layout
      1. 7.4.1 Layout Guidelines
      2. 7.4.2 Layout Example
  9. 8 Device and Documentation Support
    1. 8.1 Device Support
      1. 8.1.1 Development Support
        1. 8.1.1.1 Custom Design With WEBENCH® Tools
    2. 8.2 Documentation Support
      1. 8.2.1 Related Documentation
    3. 8.3 Receiving Notification of Documentation Updates
    4. 8.4 Support Resources
    5. 8.5 Trademarks
    6. 8.6 Electrostatic Discharge Caution
    7. 8.7 Glossary
  10. 9 Revision History
  11. 10Mechanical, Packaging, and Orderable Information
Current Limit With External Slope Compensation

RSL is used to add additional slope compensation when required. RSL is not necessary in most designs and RSL must be no larger than necessary. Select RSL according to the following equation:

Equation 20. LM3488

where

  • RSEN is the selected value based on current limit. With RSL installed, the control signal includes additional external slope to stabilize the loop, which also has an effect on the current limit threshold. Therefore, the current limit threshold must be re-verified, as illustrated in the equations below :
Equation 21. VCS = VSENSE – (D × (VSL + ΔVSL))

where

  • ΔVSL is the additional slope compensation generated and calculated as:
Equation 22. ΔVSL = 40µA × RSL

This changes the equation for current limit (or RSEN) to:

Equation 23. LM3488

The RSEN and RSL values can have to be calculated iteratively to achieve both the desired current limit and stable operation. In some designs RSL can also help to filter noise on the ISEN pin.

If the inductor is selected such that ripple current is the recommended 30% value, and the current limit threshold is 120% of the maximum peak, a simpler method can be used to determine RSEN. The equation below provides optimum stability without RSL, provided that the above two conditions are met:

Equation 24. LM3488