SNVSCP2A March 2025 – August 2025 LP5815
PRODUCTION DATA
All output channels are turned off while the LP5815 staying in THERMAL SHUTDOWN mode. The I2C interface is still active and the LP5815 enters SHUTDOWN mode when STAT is pulled low (STAT = L) and Enter Shutdown Method is applied.
When the junction temperature of LP5815 falles blow the thermal shutdown threshold, the LP5815 enters STANDBY mode when CHIP_EN = 0 or NORMAL mode when CHIP_EN = 1 after exiting from THERMAL SHUTDOWN mode. The TSD flag needs manual clear through setting TSD_CLR bit when CHIP_EN = 1.