SPRACY7 October   2021 TMS320F2800132 , TMS320F2800133 , TMS320F2800135 , TMS320F2800137 , TMS320F2800152-Q1 , TMS320F2800153-Q1 , TMS320F2800154-Q1 , TMS320F2800155 , TMS320F2800155-Q1 , TMS320F2800156-Q1 , TMS320F2800157 , TMS320F2800157-Q1 , TMS320F280033 , TMS320F280034 , TMS320F280034-Q1 , TMS320F280036-Q1 , TMS320F280036C-Q1 , TMS320F280037 , TMS320F280037-Q1 , TMS320F280037C , TMS320F280037C-Q1 , TMS320F280038-Q1 , TMS320F280038C-Q1 , TMS320F280039 , TMS320F280039-Q1 , TMS320F280039C , TMS320F280039C-Q1

 

  1.   Trademarks
  2. 1Introduction
    1. 1.1 Supplementary Information
  3. 2Clock Generator
    1. 2.1 Generating Two Offset Clocks
  4. 3Signal Generator
    1. 3.1 Two Offset Clocks Generated by the SIGGEN0 Module
    2. 3.2 Generate Serial Data With Rotate Mode
      1. 3.2.1 Rotate Right Once - CPOL = 0, CPHA = 1
      2. 3.2.2 Rotate Right Once - CPOL=0, CPHA=0
      3. 3.2.3 Rotate Right Once - CPOL=1, CPHA=1
      4. 3.2.4 Rotate Right Once - CPOL=1, CPHA=0
      5. 3.2.5 Shift Right Once - CPOL=1, CPHA=0
      6. 3.2.6 Shift Right Once - CPOL=0, CPHA=0
  5. 4Summary
  6. 5References

Rotate Right Once - CPOL=1, CPHA=1

The clock and data bit stream for CPOL=1 and CPHA=1 is shown below:

//
// Data
//
#define SIG_GEN_DATA0_0_15    0b1111000011001111U

//
// Clock - Data latched on falling edge, during idle CLK is HIGH
//
#define SIG_GEN_DATA0_16_31   0b0101010101010101U

The data bit stream in this mode is the same as CPOL=0, CPHA=1. The clock bit stream is inverted to place falling edges in between duplicated data stream bits.

GUID-20210718-CA0I-GBGK-NQQV-PWQWGTLFSV38-low.gif Figure 3-11 Rotate Right Once - CPOL=1, CPHA=1