SPRAD54 October   2022 AM2631 , AM2631-Q1 , AM2632 , AM2632-Q1 , AM2634 , AM2634-Q1

 

  1.   Abstract
  2.   Trademarks
  3. 1Using the Power Estimation Tool
  4. 2Processing Elements
  5. 3Interfaces
  6. 4Power Report

Power Report

The power estimation tool generates a power analysis report in this section. The report lists power supply name, voltage in Volts (V), and power consumption in Watts (W) per power rail groups. Power rail groups match the AM263x CC/LP design.

There is a selectable field for the junction temperature configuration:

Temperature (Tj °C): -40, 0, 25, 85, 105, 125, 140, 150.

Also, Table 4-1 shows the selectable fields for the following power rails options.

Table 4-1 Selectable Fields for Power Rails
Voltage Rail Selectable Options (V)
VDD 1.15, 1.175, 1.20,1.23, 1.25,1.28, 1.30
VDD_SRAM 1.15, 1.175, 1.20,1.23, 1.25,1.28, 1.30
VDDA 3.135,3.3,3.465