SPRZ536C September   2022  – June 2026 AM69 , AM69A , TDA4AH-Q1 , TDA4AP-Q1 , TDA4APE-Q1 , TDA4VH-Q1 , TDA4VP-Q1 , TDA4VPE-Q1

 

  1.   1
  2. 1Modules Affected
  3. 2Nomenclature, Package Symbolization, and Revision Identification
    1. 2.1 Device and Development-Support Tool Nomenclature
    2. 2.2 Devices Supported
    3. 2.3 Package Symbolization and Revision Identification
  4. 3Silicon Revision 1.0 Usage Notes and Advisories
    1. 3.1 Silicon Revision 1.0 Usage Notes
      1.      i2134
    2. 3.2 Silicon Revision 1.0 Advisories
      1.      i2049
      2.      i2062
      3.      i2063
      4.      i2064
      5.      i2065
      6.      i2079
      7.      i2087
      8.      i2097
      9.      i2102
      10.      i2103
      11.      i2120
      12.      i2134
      13.      i2137
      14.      i2146
      15.      i2157
      16.      i2159
      17.      i2160
      18.      i2161
      19.      i2163
      20.      i2166
      21.      i2177
      22.      i2189
      23.      i2190
      24.      i2196
      25.      i2197
      26.      i2205
      27.      i2215
      28.      i2216
      29.      i2219
      30.      i2232
      31.      i2234
      32.      i2242
      33.      i2244
      34.      i2249
      35.      i2253
      36.      i2271
      37.      i2272
      38.      i2278
      39.      i2279
      40.      i2310
      41.      i2311
      42.      i2312
      43.      i2320
      44.      i2326
      45.      i2330
      46.      i2351
      47.      i2362
      48.      i2366
      49.      i2371
      50.      i2372
      51.      i2378
      52.      i2381
      53.      i2383
      54.      i2399
      55.      i2401
      56.      i2409
      57.      i2413
      58.      i2414
      59.      i2415
      60.      i2419
      61.      i2422
      62.      i2424
      63.      i2431
      64.      i2435
      65.      i2436
      66.      i2437
      67.      i2449
      68.      i2459
      69.      i2482
  5.   Trademarks
  6.   Revision History

i2087


C71x: MMA HWA_STATUS Reports Errors Before Application Starts

Details:

Due to uninitialized internal state, the Matrix Math Accelerator (MMA) attached to the C71x may report errors in the FirstErrorCode and LastErrorCode fields of the HWA_STATUS register after power-on. Because these fields are sticky, any subsequent HWARCV instruction may throw a C71x exception.

Workaround(s):

After power-on, a short instruction sequence running on the C71x can initialize the internal MMA state before the first execution of normal MMA operation. Only one execution of the sequence is required.

The sequence generates a valid HWA_CONFIG and HWA_OFFSET value, loads it into the MMA, then clears the sticky error codes.

The sequence, in C71x assembly code is:

PROT 
    MVK32 .M2 0x0,B0 ; clear low word of VB0 
    VDUPW .C2 B0,VB0 ; duplicate word across VB0 
    HWAOPEN .L2 VB0,VB0,0 ; clear HWA_CONFIG and HWA_OFFSET 
    HWACLOSE .S1 0 ; clear any error conditions