SWRZ161C December   2024  – August 2026 CC2744R7-Q1 , CC2745P10-Q1 , CC2745R10-Q1 , CC2745R7-Q1

 

  1.   1
  2.   Abstract
  3.   Trademarks
  4. 1Advisories Matrix
  5. 2Nomenclature, Package Symbolization, and Revision Identification
    1. 2.1 Device and Development Support—Tool Nomenclature
    2. 2.2 Devices Supported
    3. 2.3 Package Symbolization and Revision Identification
  6. 3Advisories
    1. 3.1  ADC_08
    2. 3.2  ADC_09
    3. 3.3  BATMON_01
    4. 3.4  BATMON_02
    5. 3.5  SYS_204
    6. 3.6  SYS_206
    7. 3.7  SYS_207
    8. 3.8  SYS_211
    9. 3.9  APU_201
    10. 3.10 HSM_01
    11. 3.11 UDMA_01
    12. 3.12 RADIO_05
    13. 3.13 SYSROM_01
  7. 4Revision History

SYS_204

SysTimer may not always generate a compare event when previously programmed with a value.

Revisions Affected

E and F

Description

SysTimer does not always generate a compare event during the initialization/sync up phase, when SysTimer has previously been programmed with a value.

Workaround

Wait to program SysTimer until SYSTIM.STATUS.SYNCUP is cleared. This workaround is incorporated into the SimpleLink™ Low Power F3 software development kit (SDK) version 8.10 and newer.