Product details

Number of channels 1 Vs (max) (V) 5.5 Vs (min) (V) 1.8 Input offset (±) (max) (µV) 1300 Voltage gain (min) (V/V) 10 Voltage gain (max) (V/V) 50 Noise at 1 kHz (typ) (nV√Hz) 36 Features Cost Optimized, Low power, Small Size CMRR (min) (dB) 86 Iq (typ) (mA) 0.11 Bandwidth at min gain (typ) (MHz) 0.1 Gain error (±) (max) (%) 0.1 Operating temperature range (°C) -40 to 125 Rating Catalog Output swing headroom (to negative supply) (typ) (V) 0.015 Output swing headroom (to positive supply) (typ) (V) 0.015 Input common mode headroom (to negative supply) (typ) (V) 0 Input common mode headroom (to positive supply) (typ) (V) 0 Noise at 0.1 Hz to 10 Hz (typ) (µVPP) 3.2
Number of channels 1 Vs (max) (V) 5.5 Vs (min) (V) 1.8 Input offset (±) (max) (µV) 1300 Voltage gain (min) (V/V) 10 Voltage gain (max) (V/V) 50 Noise at 1 kHz (typ) (nV√Hz) 36 Features Cost Optimized, Low power, Small Size CMRR (min) (dB) 86 Iq (typ) (mA) 0.11 Bandwidth at min gain (typ) (MHz) 0.1 Gain error (±) (max) (%) 0.1 Operating temperature range (°C) -40 to 125 Rating Catalog Output swing headroom (to negative supply) (typ) (V) 0.015 Output swing headroom (to positive supply) (typ) (V) 0.015 Input common mode headroom (to negative supply) (typ) (V) 0 Input common mode headroom (to positive supply) (typ) (V) 0 Noise at 0.1 Hz to 10 Hz (typ) (µVPP) 3.2
WSON (DSG) 8 4 mm² 2 x 2
  • Fixed gain of 10V/V instrumentation amp with configurable reference amp
  • INA performance for 10-bit to 14-bit systems
    • CMRR: 95 dB (typical)
    • Gain error: 0.015% (typical)
    • Bandwidth: 100 kHz (typical)
  • Reference amp can be used for:
    • External DC error calibration with servo loop
    • Providing buffered voltage of external circuits
    • Filtering or adjustment of reference voltage
  • Ultra-small package option (2mm x 2mm)
  • Drives 1 nF with under 10% overshoot (typical)
  • Optimized quiescent current: 110 µA (typical)
  • Supply range: 1.8 V (±0.9 V) to 5.5 V (±2.75 V)
  • Specified temperature range: –40°C to 125°C
  • Fixed gain of 10V/V instrumentation amp with configurable reference amp
  • INA performance for 10-bit to 14-bit systems
    • CMRR: 95 dB (typical)
    • Gain error: 0.015% (typical)
    • Bandwidth: 100 kHz (typical)
  • Reference amp can be used for:
    • External DC error calibration with servo loop
    • Providing buffered voltage of external circuits
    • Filtering or adjustment of reference voltage
  • Ultra-small package option (2mm x 2mm)
  • Drives 1 nF with under 10% overshoot (typical)
  • Optimized quiescent current: 110 µA (typical)
  • Supply range: 1.8 V (±0.9 V) to 5.5 V (±2.75 V)
  • Specified temperature range: –40°C to 125°C

INA351A is a fixed gain of 10 instrumentation amplifier with a configurable reference amplifier in a small package. This instrumentation amp (INA) is built with precision-matched resistors to achieve excellent CMRR and gain error performance in a small, low-cost form factor. This makes INA351A a great solution to replace discrete INA implementations to achieve higher performance and more compact designs with minimal impact to bill of materials (BOM) costs.

The integrated, configurable reference amplifier can be used as a buffer for external use or as part of a closed-loop calibration circuit to achieve better DC precision. The closed-loop calibration can be accomplished by implementing a servo loop amplifier to calibrate DC errors from sensors (like offset, offset drift and so forth) at the INA output when the INA input signal is at a slightly higher frequency than DC depending on the application.

INA351A achieves 86 dB of minimum CMRR, an accurate 0.1% of maximum gain error and only consumes a maximum of 135 µA quiescent current at room temperature. The INA can directly drive sub-1 kHz, 10-bit to 14-bit, delta-sigma analog-to-digital converters (ADC) without an ADC driver, making it a great choice for portable, battery-powered medical applications like electrocardiograms or wearable health monitors.

INA351A is a fixed gain of 10 instrumentation amplifier with a configurable reference amplifier in a small package. This instrumentation amp (INA) is built with precision-matched resistors to achieve excellent CMRR and gain error performance in a small, low-cost form factor. This makes INA351A a great solution to replace discrete INA implementations to achieve higher performance and more compact designs with minimal impact to bill of materials (BOM) costs.

The integrated, configurable reference amplifier can be used as a buffer for external use or as part of a closed-loop calibration circuit to achieve better DC precision. The closed-loop calibration can be accomplished by implementing a servo loop amplifier to calibrate DC errors from sensors (like offset, offset drift and so forth) at the INA output when the INA input signal is at a slightly higher frequency than DC depending on the application.

INA351A achieves 86 dB of minimum CMRR, an accurate 0.1% of maximum gain error and only consumes a maximum of 135 µA quiescent current at room temperature. The INA can directly drive sub-1 kHz, 10-bit to 14-bit, delta-sigma analog-to-digital converters (ADC) without an ADC driver, making it a great choice for portable, battery-powered medical applications like electrocardiograms or wearable health monitors.

Download View video with transcript Video

Technical documentation

star =Top documentation for this product selected by TI
No results found. Please clear your search and try again.
View all 1
Top documentation Type Title Format options Date
* Data sheet INA351A - Low Power, 1.8-V to 5.5-V Small-Size Instrumentation Amplifier with Configurable Reference Amplifier datasheet PDF | HTML 12 Jun 2023

Design & development

For additional terms or required resources, click any title below to view the detail page where available.

Evaluation board

SMALL-AMP-DIP-EVM — Evaluation module for operational amplifiers with small-size packages

The SMALL-AMP-DIP-EVM speeds up small-package operational-amplifier prototyping by providing a fast and easy way to interface with many industry-standard small-size packages. SMALL-AMP-DIP-EVM supports eight small package options including DPW-5 (X2SON), DSG-8 (WSON), DCN-8 (SOT), DDF-8 (...)

User guide: PDF
Not available on TI.com
Simulation model

INA351A PSpice Reference Design

SBOMCE8.ZIP (7 KB) - PSpice Model
Simulation model

INA351A TINA-TI Reference Design

SBOMCE7.TSC (48 KB) - TINA-TI Reference Design
Simulation model

INA351A TINA-TI SPICE Model

SBOMCE9.ZIP (7 KB) - TINA-TI Spice Model
Calculation tool

ANALOG-ENGINEER-CALC PC software analog engineer's calculator

The analog engineer’s calculator is designed to speed up many of the repetitive calculations that analog circuit design engineers use on a regular basis. This PC-based tool provides a graphical interface with a list of various common calculations ranging from setting operational-amplifier (...)

Supported products & hardware

Supported products & hardware

Simulation tool

PSPICE-FOR-TI — PSpice® for TI design and simulation tool

PSpice® for TI is a design and simulation environment that helps evaluate functionality of analog circuits. This full-featured, design and simulation suite uses an analog analysis engine from Cadence®. Available at no cost, PSpice for TI includes one of the largest model libraries in the (...)
Simulation tool

TINA-TI — SPICE-based analog simulation program

TINA-TI provides all the conventional DC, transient and frequency domain analysis of SPICE and much more. TINA has extensive post-processing capability that allows you to format results the way you want them. Virtual instruments allow you to select input waveforms and probe circuit nodes voltages (...)
User guide: PDF
Package Pins CAD symbols, footprints & 3D models
WSON (DSG) 8 Ultra Librarian

Ordering & quality

Information included:
  • RoHS
  • REACH
  • Device marking
  • Lead finish/Ball material
  • MSL rating/Peak reflow
  • MTBF/FIT estimates
  • Material content
  • Qualification summary
  • Ongoing reliability monitoring
Information included:
  • Fab location
  • Assembly location

Support & training

TI E2E™ forums with technical support from TI engineers

Content is provided "as is" by TI and community contributors and does not constitute TI specifications. See terms of use.

If you have questions about quality, packaging or ordering TI products, see TI support. ​​​​​​​​​​​​​​

Videos