TVS2200
- Protection against ±1 kV, 42 Ω IEC 61000-4-5 surge test for industrial signal lines
- Maximum clamping voltage of 28.4 V at 40 A of 8/20 µs surge current
- Standoff voltage: 22 V
- Tiny 4 mm 2 footprint
- Survives over 5,000 repetitive strikes of 35 A 8/20 µs surge current at 125°C
- Robust surge protection:
- IEC 61000-4-5 (8/20 µs): 40 A
- IEC 61643-321 (10/1000 µs): 5 A
- Low leakage current:
- 3.5 nA typical at 27°C
- 25 nA typical at 85°C
- Low capacitance: 105 pF
- Integrated level 4 IEC 61000-4-2 ESD protection
The TVS2200 robustly shunts up to 40 A of IEC 61000-4-5 fault current to protect systems from high power transients or lightning strikes. The device offers a solution to the common industrial signal line EMC requirement to survive up to ±1 kV IEC 61000-4-5 open circuit voltage coupled through a 42 Ω impedance.
The TVS2200 uses a unique feedback mechanism for precise flat clamping during a fault, allowing system exposure below 30 V. The tight voltage regulation allows designers to confidently select system components with a lower voltage tolerance, lowering system costs and complexity without sacrificing robustness.
In addition, the TVS2200 is available in a small 2 mm × 2 mm SON footprint which is designed for space constrained applications, offering a 70 percent reduction in size compared to industry standard SMA and SMB packages. The extremely low device leakage and capacitance causes a minimal effect on the protected line. For robust protection over the lifetime of the product, TI tests the TVS2200 against 5,000 repetitive surge strikes at high temperature with no shift in device performance.
The TVS2200 is part of TIs Flat-Clamp family of surge devices. For more information on the other devices in the family, see the Device Comparison Table.
技術文件
| 重要文件 | 類型 | 標題 | 格式選項 | 下載最新的英文版本 | 日期 | |
|---|---|---|---|---|---|---|
| * | 資料表 | TVS2200 22-V Flat-Clamp Surge Protection Device datasheet (Rev. C) | PDF | HTML | 2023/8/14 | ||
| 應用說明 | ESD and Surge Protection for USB Interfaces (Rev. B) | PDF | HTML | 2024/1/11 | |||
| 應用說明 | ESD Packaging and Layout Guide (Rev. B) | PDF | HTML | 2022/8/18 | |||
| 使用指南 | Generic ESD Evaluation Module User's Guide (Rev. A) | PDF | HTML | 2021/9/27 | |||
| Application brief | Protecting I/O modules from surge events | 2019/2/4 | ||||
| Application brief | TVS Surge Rating: Power vs. Current | 2018/11/12 | ||||
| 白皮書 | Demystifying surge protection | 2018/11/6 | ||||
| 使用指南 | Flat Clamp TVS Evaluation Module—Adaptor Boards | 2018/9/10 | ||||
| 應用說明 | How to select a Surge Diode | 2018/8/29 | ||||
| Application brief | Flat-Clamp TVS Layout in SMA/SMB Footprints | 2018/4/3 | ||||
| 應用說明 | TVS Surge Protection in High-Temperature Environments | 2018/3/23 | ||||
| 白皮書 | Flat-Clamp surge protection technology for efficient system protection | 2018/1/15 |
設計與開發
如需其他條款或必要資源,請按一下下方的任何標題以檢視詳細頁面 (如有)。
FLAT-CLAMP-TVS-EVM — TVSxx0x 精密突波防護二極體評估模組
TIDA-010008 — 適合電網應用瞬態保護的平箝制 TVS 架構參考設計
TIDA-050047 — 整合式 USB Type-C®、USB 電力輸送和 2-4 芯電池的充電參考設計
此參考設計可在 5 A 電流下充電至 20 V,無需任何外部 FET,進而大幅縮小解決方案尺寸,並降低總 BOM 成本。此外也不需要微處理器,因為 TPS25750 電力輸送 (PD) 控制器會處理與 BQ25798 電池充電器 IC 的 I2C 通訊。此 I2C 功能與 TPS25750 Web 架構 GUI 可大幅簡化韌體開發程序。
| 封裝 | 針腳 | CAD 符號、佔位空間與 3D 模型 |
|---|---|---|
| WSON (DRV) | 6 | Ultra Librarian |
訂購與品質
建議產品可能具有與此 TI 產品相關的參數、評估模組或參考設計。