The TI Embedded Processor Software Toolkit for Medical Imaging (STK-MED) is a collection of several standard ultrasound and optical coherence tomography (OCT) algorithms for TI’s C66x™ and C64x+™ architecture. The algorithms showcase how medical imaging functions can leverage the C66x and C64x+ architecture for efficient performance and low power consumption. The goal of STK-MED is to shorten customer development time of medical imaging systems by providing optimized implementations of commonly used processing blocks. The source code contained in the STK-MED can easily be extended or modified to develop customized and differentiated modules.
Merkmale

The STK-MED contains optimized software for processing blocks commonly found in ultrasound and OCT medical imaging system. The STK-MED contains a detailed algorithm description with API documentation, benchmarks and a unit test bench for each software module.

The unit test benches can be run on both C6678 and C6472 EVM target devices.

The STK-MED includes the following optimized modules:

  • B-Mode processing for ultrasound
  • Doppler Processing functions for 1D Color Flow, 2D Color Flow, Wall Filter and Power Estimator for ultrasound
  • RF demodulation and decimation for ultrasound
  • Scan Conversion for ultrasound
  • Cubic Spline Interpolation for OCT
  • FFT and IFFT for OCT
  • Magnitude Computation for OCT
  • Log Computation for OCT
  • Optimized math utilities including affine wrap
Herunterladen Video mit Transkript ansehen Video

Downloads

Software-Entwicklungskit (SDK)

MEDIMGSTK-C66X TI Embedded Processor Software Tool Kit for Medical Imaging (STK-MED) - for C66x and C64x+ based processors

Unterstützte Produkte und Hardware

Unterstützte Produkte und Hardware

Produkte
Audio- & Radar-DSP-SoCs
DM505 SoC für Vision Analytics 15mm-Gehäuse SM320C6678-HIREL Hochzuverlässiges Produkt mit hoher Leistung, 8-Kern-C6678 Fest- und Gleitkomma-DSP TMS320C6454 C64x+ Festkomma-DSP – bis zu 1 GHz, 64-Bit EMIFA, 32/16 Bit DDR2, 1 Gbps-Ethernet TMS320C6455 C64x+ Festkomma-DSP – bis zu 1,2 GHz, 64-Bit EMIFA, 32/16 Bit DDR2, Ethernet 1Gbit/s TMS320C6457 Digitaler Signalprozessor für die Kommunikationsinfrastruktur
Multimedia- & Industrienetzwerk-SoCs
TMS320C6472 Digitaler Festkomma-Signalprozessor TMS320C6474 Digitaler Signalprozessor mit mehreren Kernen
Download-Optionen

MEDIMGSTK-C66X TI Embedded Processor Software Tool Kit for Medical Imaging (STK-MED) - for C66x and C64x+ based processors

close
Aktuelle Version
Version: 03.00.00
Veröffentlichungsdatum: 03.11.2011

STK-MED for C64x+ and C66x Windows Installer

SHA-256-Prüfsumme
Produkte
Audio- & Radar-DSP-SoCs
DM505 SoC für Vision Analytics 15mm-Gehäuse SM320C6678-HIREL Hochzuverlässiges Produkt mit hoher Leistung, 8-Kern-C6678 Fest- und Gleitkomma-DSP TMS320C6454 C64x+ Festkomma-DSP – bis zu 1 GHz, 64-Bit EMIFA, 32/16 Bit DDR2, 1 Gbps-Ethernet TMS320C6455 C64x+ Festkomma-DSP – bis zu 1,2 GHz, 64-Bit EMIFA, 32/16 Bit DDR2, Ethernet 1Gbit/s TMS320C6457 Digitaler Signalprozessor für die Kommunikationsinfrastruktur
Multimedia- & Industrienetzwerk-SoCs
TMS320C6472 Digitaler Festkomma-Signalprozessor TMS320C6474 Digitaler Signalprozessor mit mehreren Kernen

Versionsinformationen

The TI Embedded Processor Software Toolkit for Medical Imaging (STK-MED) is a collection of several standard ultrasound and optical coherence tomography (OCT) algorithms for TI's C66x and C64x+ architecture. The algorithms showcase how medical imaging functions can leverage the C66x and C64x+ architecture for efficient performance and low power consumption. The goal of STK-MED is to shorten customer development time of medical imaging systems by providing optimized implementations of commonly used processing blocks. The source code contained in the STK-MED can easily be extended or modified to develop customized and differentiated modules. Please see the landing page, https://www.ti.com/tool/s2meddus for feature details.

Additional Information

* Support Forum: Please post your question at https://e2e.ti.com/support/embedded/f/355.aspx and include tag "STK-MED".

Technical Documents

* Documentation is included within the package.

Note

* Please do not install in the same directory as .exe file.

Legal Disclaimer

System and equipment manufacturers and designers are responsible to ensure that their systems (and any TI devices incorporated in their systems) meet all applicable safety, regulatory and system-level performance requirements. All application-related information on this website (including application descriptions, suggested TI devices and other materials) is provided for reference only. While we have taken care to assure it is accurate, this information is subject to customer confirmation, and TI disclaims all liability for system designs and for any applications assistance provided by TI. Use of TI devices in life support and/or safety applications is entirely at the buyer's risk, and the buyer agrees to defend, indemnify and hold harmless TI from any and all damages, claims, suits or expense resulting from such use.

Technische Dokumentation

Keine Ergebnisse gefunden. Bitte geben Sie einen anderen Begriff ein und versuchen Sie es erneut.
Alle anzeigen 21
Typ Titel Neueste englische Version herunterladen Datum
Weitere Dokumente Picture it: DSPs in medical imaging (Rev. C) 12.07.2013
Whitepaper Medical Software Development on Keystone Devices 12.07.2013
Whitepaper Another Look at the Future of Medical Processing 12.07.2013
Weitere Dokumente Medical Imaging Tools provide fast, easy ultrasound development (Rev. B) 20.01.2012
Anwendungshinweis Algorithms for Optical Coherence Tomography on TMS320C64x+ 08.06.2010
Anwendungshinweis Implementation of Affine Warp Using TI DSP 08.06.2010
Anwendungshinweis Using TI's Embedded Processor Software Toolkit for Medical Imaging (MED-STK) 08.06.2010
Weitere Dokumente Embedded Processor Software Toolkit for Medical Imaging Ver 2.0 08.06.2010
Whitepaper Multicore processors bring innovation to portable medical imaging systems 08.06.2010
Product overview Receive Beamformer (RXBF) Data Sheet 28.10.2009
Anwendungshinweis Wall Filter for Color Flow 28.10.2009
Product overview RF Demodulator Data Sheet 28.10.2009
Anwendungshinweis Doppler Power Estimator 28.10.2009
Product overview Doppler Color Flow Estimator (1D) Data Sheet 28.10.2009
Anwendungshinweis Doppler Color Flow Estimator (2D) 28.10.2009
Product overview Four Quadrant Inverse Tangent (Low Precision) Product Brief 28.10.2009
Weitere Dokumente Scan Converter Software Release Notes 28.10.2009
Weitere Dokumente Medical Diagnostic Ultrasound Software 28.10.2009
Anwendungshinweis Ultrasound Scan Conversion on TI's C64x+ DSPs 03.04.2009
Anwendungshinweis Digital Signal Processor (DSP) for Portable Ultrasound (Rev. A) 18.12.2008
Anwendungshinweis Efficient Implementation of Ultrasound Color Doppler Algorithms on TI C64x 07.11.2008

Support und Schulungen

TI E2E™-Foren mit technischem Support von TI-Ingenieuren

Alle Forenthemen auf Englisch anzeigen

Inhalte werden ohne Gewähr von TI und der Community bereitgestellt. Sie stellen keine Spezifikationen von TI dar. Siehe Nutzungsbedingungen.

Bei Fragen zu den Themen Qualität, Gehäuse oder Bestellung von TI-Produkten siehe TI-Support.