JAJSF28B July   2014  – March 2018 ONET2804T

PRODUCTION DATA.  

  1. 特長
  2. アプリケーション
  3. 概要
    1.     Device Images
      1.      概略回路図
      2.      アイ・ダイアグラム
  4. 改訂履歴
  5. Pin Configuration and Functions
    1.     Bond Pad Functions
  6. Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 DC Electrical Characteristics
    5. 6.5 AC Electrical Characteristics
    6. 6.6 Typical Characteristics
  7. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 Signal Path
      2. 7.3.2 Gain Adjustment
      3. 7.3.3 Amplitude Adjustment
      4. 7.3.4 Rate Select
      5. 7.3.5 Threshold Adjustment
      6. 7.3.6 Filter Circuitry
      7. 7.3.7 AGC and RSSI
    4. 7.4 Device Functional Modes
      1. 7.4.1 Pad Control
      2. 7.4.2 2-Wire Interface Control
      3. 7.4.3 2-Wire Interface and Control Logic
      4. 7.4.4 Bus Idle
      5. 7.4.5 Start Data Transfer
      6. 7.4.6 Stop Data Transfer
      7. 7.4.7 Data Transfer
      8. 7.4.8 Acknowledge
    5. 7.5 Register Maps
      1. 7.5.1  Register 0 (0x00) – Control Settings (offset = 0h) [reset = 0h]
        1. Table 2. Register 0 (0x00) – Control Settings Field Descriptions
      2. 7.5.2  Register 1 (0x01) – Amplitude and Rate for Channel 1 (offset = 1h) [reset = 0h]
        1. Table 3. Register 1 (0x01) – Amplitude and Rate for Channel 1 Field Descriptions
      3. 7.5.3  Register 2 (0x02) Mapping – Threshold and Gain for Channel 1 (offset = 2h) [reset = 0h]
        1. Table 4. Register 2 (0x02) – Threshold and Gain for Channel 1
      4. 7.5.4  Register 3 (0x03) – Reserved
        1. Table 5. Register 3 (0x03) – Reserved Field Descriptions
      5. 7.5.5  Register 4 (0x04) – Reserved
        1. Table 6. Register 4 (0x04) – Reserved Field Descriptions
      6. 7.5.6  Register 5 (0x05) – Reserved
        1. Table 7. Register 5 (0x05) – Reserved Field Descriptions
      7. 7.5.7  Register 6 (0x06) – Reserved
        1. Table 8. Register 6 (0x06) – Reserved Field Descriptions
      8. 7.5.8  Register 7 (0x07) – Amplitude and Rate for Channel 2 (offset = 7h) [reset = 0h]
        1. Table 9. Register 7 (0x07) – Amplitude and Rate for Channel 2 Field Descriptions
      9. 7.5.9  Register 8 (0x08) Mapping – Threshold and Gain for Channel 1 (offset = 8h) [reset = 0h]
        1. Table 10. Register 8 (0x08) – Threshold and Gain for Channel 2
      10. 7.5.10 Register 9 (0x09) – Reserved
        1. Table 11. Register 9 (0x09) – Reserved Field Descriptions
      11. 7.5.11 Register 10 (0x0A) – Reserved
        1. Table 12. Register 10 (0x0A) – Reserved Field Descriptions
      12. 7.5.12 Register 11 (0x0B) – Reserved
        1. Table 13. Register 11 (0x0B) – Reserved Field Descriptions
      13. 7.5.13 Register 12 (0x0C) – Reserved
        1. Table 14. Register 12 (0x0C) – Reserved Field Descriptions
      14. 7.5.14 Register 13 (0x0D) – Amplitude and Rate for Channel 3 (offset = Dh) [reset = 0h]
        1. Table 15. Register 13 (0x0D) – Amplitude and Rate for Channel 3 Field Descriptions
      15. 7.5.15 Register 14 (0x0E) Mapping – Threshold and Gain for Channel 3 (offset = Eh) [reset = 0h]
        1. Table 16. Register 14 (0x0E) – Threshold and Gain for Channel 3
      16. 7.5.16 Register 15 (0x0F) – Reserved
        1. Table 17. Register 15 (0x0F) – Reserved Field Descriptions
      17. 7.5.17 Register 16 (0x10) – Reserved
        1. Table 18. Register 16 (0x10) – Reserved Field Descriptions
      18. 7.5.18 Register 17 (0x11) – Reserved
        1. Table 19. Register 17 (0x11) – Reserved Field Descriptions
      19. 7.5.19 Register 18 (0x12) – Reserved
        1. Table 20. Register 18 (0x12) – Reserved Field Descriptions
      20. 7.5.20 Register 19 (0x13) – Amplitude and Rate for Channel 4 (offset = 13h ) [reset = 0h]
        1. Table 21. Register 19 (0x13) – Amplitude and Rate for Channel 4 Field Descriptions
      21. 7.5.21 Register 20 (0x14) Mapping – Threshold and Gain for Channel 4 (offset =14h) [reset = 0h]
        1. Table 22. Register 20 (0x14) – Threshold and Gain for Channel 4
      22. 7.5.22 Register 21 (0x15) – Reserved
        1. Table 23. Register 21 (0x15) – Reserved Field Descriptions
      23. 7.5.23 Register 22 (0x10) – Reserved
        1. Table 24. Register 21 (0x10) – Reserved Field Descriptions
      24. 7.5.24 Register 23 (0x17) – Reserved
        1. Table 25. Register 23 (0x17) – Reserved Field Descriptions
      25. 7.5.25 Register 24 (0x18) – Reserved
        1. Table 26. Register 24 (0x18) – Reserved Field Descriptions
      26. 7.5.26 Register 25 (0x19) – Reserved
        1. Table 27. Register 25 (0x19) – Reserved Field Descriptions
  8. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Applications
      1. 8.2.1 Typical Application, Pad Control
        1. 8.2.1.1 Design Requirements
        2. 8.2.1.2 Detailed Design Procedure
        3. 8.2.1.3 Application Curves
      2. 8.2.2 Typical Application, 2-Wire Control
        1. 8.2.2.1 Design Requirements
        2. 8.2.2.2 Detailed Design Procedure
        3. 8.2.2.3 Application Curves
  9. Power Supply Recommendations
  10. 10Layout
    1. 10.1 Layout Guidelines
    2. 10.2 Layout Example
  11. 11デバイスおよびドキュメントのサポート
    1. 11.1 ドキュメントの更新通知を受け取る方法
    2. 11.2 コミュニティ・リソース
    3. 11.3 商標
    4. 11.4 静電気放電に関する注意事項
    5. 11.5 Glossary
  12. 12メカニカル、パッケージ、および注文情報

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
  • Y|0
サーマルパッド・メカニカル・データ
発注情報

概要

ONET2804Tは、並列光学相互接続用の高ゲインの制限付きトランスインピーダンス・アンプで、データ・レートは最高28Gbpsです。このデバイスは、750μmピッチのフォトダイオード・アレイと組み合わせて、光信号を差動出力電圧へ変換するために使用されます。内部回路によってフォトダイオードの逆バイアス電圧を供給し、各フォトダイオードに供給される平均光電流を検出します。

このデバイスは、ピン制御または2線式シリアル・インターフェイスで使用でき、出力振幅、ゲイン、帯域幅、入力スレッショルドを制御できます。

ONET2804Tは、チャネルごとに21GHzの帯域幅、10kΩのゲイン、1.8µArmsの入力換算ノイズ、および各チャネルの受信信号強度インジケータ(RSSI)を提供します。40dBのチャネル間絶縁により、レシーバでのクロストーク・ペナルティが低くなります。

この部品には単一の3.3V電源が必要で、500mVPPの差動出力振幅で通常はチャネルごとに139mWを消費します。-40℃~+100℃で動作が規定されており、チャネル・ピッチ750μmのダイ形式で供給されます。

完全なデータシートは、onet2804t_request@ti.comに電子メールでご請求ください。

製品情報(1)

型番 パッケージ 本体サイズ(公称)
ONET2804T ワッフル・パックのベース・ダイ 3250µm×1450µm