ISO1042

AKTIV

Isolierter CAN-Transceiver mit 70-V-Busfehlerschutz und flexibler Datenrate

Produktdetails

Rating Catalog Isolation rating Basic, Reinforced Data rate (max) (Mbps) 5 Working isolation voltage (VIOWM) (Vrms) 1060 Surge isolation voltage (VIOSM) (VPK) 6000, 10000 Transient isolation voltage (VIOTM) (VPK) 7071 Withstand isolation voltage (VISO) (Vrms) 5000 CMTI (min) (kV/µs) 85 Supply voltage (V) 1.71 to 5.5, 4.5 to 5.5 Bus fault voltage (V) -70 to 70 Common-mode voltage (V) -30 to 30 ESD HBM (kV) 16 Creepage (min) (mm) 8, 8.5 Clearance (min) (mm) 8, 8.5 Operating temperature range (°C) -40 to 125
Rating Catalog Isolation rating Basic, Reinforced Data rate (max) (Mbps) 5 Working isolation voltage (VIOWM) (Vrms) 1060 Surge isolation voltage (VIOSM) (VPK) 6000, 10000 Transient isolation voltage (VIOTM) (VPK) 7071 Withstand isolation voltage (VISO) (Vrms) 5000 CMTI (min) (kV/µs) 85 Supply voltage (V) 1.71 to 5.5, 4.5 to 5.5 Bus fault voltage (V) -70 to 70 Common-mode voltage (V) -30 to 30 ESD HBM (kV) 16 Creepage (min) (mm) 8, 8.5 Clearance (min) (mm) 8, 8.5 Operating temperature range (°C) -40 to 125
SOIC (DW) 16 106.09 mm² 10.3 x 10.3 SOIC (DWV) 8 67.275 mm² 5.85 x 11.5
  • Meets the ISO 11898-2:2016 physical layer standard
  • Supports classic CAN up to 1 Mbps and FD (Flexible Data Rate) up to 5 Mbps
  • Low loop delay: 152 ns
  • Protection features
    • DC bus fault protection voltage: ±70 V
    • HBM ESD tolerance on bus pins: ±16 kV
    • Driver Dominant Time Out (TXD DTO)
    • Undervoltage protection on VCC1 and VCC2
  • Common-Mode Voltage Range: ±30 V
  • Ideal passive, high impedance bus terminals when unpowered
  • High CMTI: 100 kV/µs
  • VCC1 voltage range: 1.71 V to 5.5 V
    • Supports 1.8-V, 2.5-V, 3.3-V and 5.0-V logic interface to the CAN controller
  • VCC2 Voltage Range: 4.5 V to 5.5 V
  • Robust Electromagnetic Compatibility (EMC)
    • System-level ESD, EFT, and surge immunity
    • Low emissions
  • Ambient Temperature Range: –40°C to +125°C
  • 16-SOIC and 8-SOIC package options
  • Automotive version available: ISO1042-Q1
  • Safety-related certifications:
    • 7071-VPK VIOTM and 1500-VPK VIORM (Reinforced and Basic Options) per DIN VDE V 0884-11:2017-01
    • 5000-VRMS Isolation for 1 Minute per UL 1577
    • IEC 60950-1, IEC 60601-1 and EN 61010-1 certifications
    • CQC, TUV and CSA certifications
  • Meets the ISO 11898-2:2016 physical layer standard
  • Supports classic CAN up to 1 Mbps and FD (Flexible Data Rate) up to 5 Mbps
  • Low loop delay: 152 ns
  • Protection features
    • DC bus fault protection voltage: ±70 V
    • HBM ESD tolerance on bus pins: ±16 kV
    • Driver Dominant Time Out (TXD DTO)
    • Undervoltage protection on VCC1 and VCC2
  • Common-Mode Voltage Range: ±30 V
  • Ideal passive, high impedance bus terminals when unpowered
  • High CMTI: 100 kV/µs
  • VCC1 voltage range: 1.71 V to 5.5 V
    • Supports 1.8-V, 2.5-V, 3.3-V and 5.0-V logic interface to the CAN controller
  • VCC2 Voltage Range: 4.5 V to 5.5 V
  • Robust Electromagnetic Compatibility (EMC)
    • System-level ESD, EFT, and surge immunity
    • Low emissions
  • Ambient Temperature Range: –40°C to +125°C
  • 16-SOIC and 8-SOIC package options
  • Automotive version available: ISO1042-Q1
  • Safety-related certifications:
    • 7071-VPK VIOTM and 1500-VPK VIORM (Reinforced and Basic Options) per DIN VDE V 0884-11:2017-01
    • 5000-VRMS Isolation for 1 Minute per UL 1577
    • IEC 60950-1, IEC 60601-1 and EN 61010-1 certifications
    • CQC, TUV and CSA certifications

The ISO1042 device is a galvanically-isolated controller area network (CAN) transceiver that meets the specifications of the ISO11898-2 (2016) standard. The ISO1042 device offers ±70-V DC bus fault protection and ±30-V common-mode voltage range. The device supports up to 5-Mbps data rate in CAN FD mode allowing much faster transfer of payload compared to classic CAN. This device uses a silicon dioxide (SiO2) insulation barrier with a withstand voltage of 5000 VRMS and a working voltage of 1060 VRMS. Electromagnetic compatibility has been significantly enhanced to enable system-level ESD, EFT, surge, and emissions compliance. Used in conjunction with isolated power supplies, the device protects against high voltage, and prevents noise currents from the bus from entering the local ground. The ISO1042 device is available for both basic and reinforced isolation (see Reinforced and Basic Isolation Options). The ISO1042 device supports a wide ambient temperature range of –40°C to +125°C. The device is available in the SOIC-16 (DW) package and a smaller SOIC-8 (DWV) package.

The ISO1042 device is a galvanically-isolated controller area network (CAN) transceiver that meets the specifications of the ISO11898-2 (2016) standard. The ISO1042 device offers ±70-V DC bus fault protection and ±30-V common-mode voltage range. The device supports up to 5-Mbps data rate in CAN FD mode allowing much faster transfer of payload compared to classic CAN. This device uses a silicon dioxide (SiO2) insulation barrier with a withstand voltage of 5000 VRMS and a working voltage of 1060 VRMS. Electromagnetic compatibility has been significantly enhanced to enable system-level ESD, EFT, surge, and emissions compliance. Used in conjunction with isolated power supplies, the device protects against high voltage, and prevents noise currents from the bus from entering the local ground. The ISO1042 device is available for both basic and reinforced isolation (see Reinforced and Basic Isolation Options). The ISO1042 device supports a wide ambient temperature range of –40°C to +125°C. The device is available in the SOIC-16 (DW) package and a smaller SOIC-8 (DWV) package.

Herunterladen Video mit Transkript ansehen Video

Ähnliche Produkte, die für Sie interessant sein könnten

Selbe Funktionalität wie der verglichene Baustein bei abweichender Anschlussbelegung
ISO1044 AKTIV Isolierter CAN FD-Transceiver in kleinem Gehäuse 3-kVrms isolated CAN transceiver with data rate up to 5-Mbps CAN FD, 58-V bus fault protection and smallest package (4.90mm x 3.91mm)

Technische Dokumentation

star =Von TI ausgewählte Top-Empfehlungen für dieses Produkt
Keine Ergebnisse gefunden. Bitte geben Sie einen anderen Begriff ein und versuchen Sie es erneut.
Alle anzeigen 23
Typ Titel Datum
* Data sheet ISO1042 Isolated CAN Transceiver With 70-V Bus Fault Protection and Flexible Data Rate datasheet (Rev. E) PDF | HTML 28 Okt 2019
Certificate VDE Certificate for Reinforced Isolation for DIN EN IEC 60747-17 (Rev. S) 29 Feb 2024
Certificate VDE Certificate for Basic Isolation for DIN EN IEC 60747-17 (Rev. W) 31 Jan 2024
White paper Understanding failure modes in isolators (Rev. B) PDF | HTML 29 Jan 2024
Certificate CQC Certificate for ISOxxDWx (Rev. J) 27 Mär 2023
Certificate CSA Certificate for ISO1042xDW 16 Mär 2023
Certificate CSA Certificate for ISO1042xDWV 16 Mär 2023
Certificate CQC Certificate for ISOxxDWV (Rev. A) 07 Feb 2023
Product overview Isolating a CAN Bus (Rev. A) PDF | HTML 13 Jan 2023
Certificate TUV Certificate for Isolation Devices (Rev. K) 05 Aug 2022
Certificate UL Certificate of Compliance File E181974 Vol 4 Sec 6 (Rev. P) 05 Aug 2022
Application brief Isolate Your CAN Systems Without Compromising on Performance or Space (Rev. F) PDF | HTML 04 Aug 2022
White paper Why are Digital Isolators Certified to Meet Electrical Equipment Standards? 16 Nov 2021
White paper Distance Through Insulation: How Digital Isolators Meet Certification Requiremen PDF | HTML 11 Jun 2021
Application brief How to Isolate Signal and Power in Isolated CAN Systems (Rev. C) PDF | HTML 25 Mai 2021
Application note Top Design Questions about Isolating CAN Nodes Bus Design (Rev. A) PDF | HTML 19 Mai 2021
Application note Isolated CAN Reference Design (Rev. E) 22 Jul 2020
Technical article Now that you have isolated your CAN signals, what about power? PDF | HTML 09 Jan 2019
Technical article 5 ways TI’s tiny devices deliver huge innovations to engineers PDF | HTML 08 Nov 2018
Technical article Reduce emissions and drive up immunity in your isolated CAN systems PDF | HTML 07 Nov 2018
EVM User's guide ISO1042DWV Isolated CAN Transceiver Evaluation Module 11 Jul 2018
EVM User's guide ISO1042DW Isolated CAN Transceiver Evaluation Module (Rev. A) 09 Jul 2018
Application note How to Design Isolated CAN Systems With Correct Bus Protection 19 Jun 2018

Design und Entwicklung

Weitere Bedingungen oder erforderliche Ressourcen enthält gegebenenfalls die Detailseite, die Sie durch Klicken auf einen der unten stehenden Titel erreichen.

Evaluierungsplatine

ISO1042DWEVM — ISO1042DW Hochgeschwindigkeits-, Hochleistungs- und robustes EMV-isoliertes CAN-Evaluierungsmodul

ISO1042DWEVM is an evaluation module used to evaluate the high performance, reinforced isolated CAN ISO1042 in a 16-pin wide body SOIC package (package code DW). The EVM features enough test points and jumper options to evaluate the device with minimal external components.

Benutzerhandbuch: PDF
Evaluierungsplatine

ISO1042DWVEVM — ISO1042DWV Hochgeschwindigkeits-, Hochleistungs- und robustes EMV-isoliertes CAN-Evaluierungsmodul

ISO1042DWVEVM is an evaluation module used to evaluate the high performance, reinforced isolated CAN ISO1042 in an 8-pin wide body SOIC package (package code DWV). The EVM features enough test points and jumper options to evaluate the device with minimal external components.
Benutzerhandbuch: PDF
Evaluierungsplatine

RECOM-3P-R-REF03-CAN1 — Recom-isolierte CAN- und Stromversorgungs-Referenzplatine mit isolierten DC/DC-Wandlern ISO1042 und

Recom's R-REF03-CAN1 reference board allows design engineers to quickly develop and analyze isolated CAN bus systems. It includes the galvanically-isolated ISO1042 CAN transceiver, which supports up to 5-Mbps data rate in CAN FD mode allowing much faster transfer of payload compared to classic (...)
Simulationsmodell

ISO1042 IBIS Model

SLLM395.ZIP (84 KB) - IBIS Model
Simulationsmodell

ISO1042 PSpice Model

SLLM507.ZIP (10 KB) - PSpice Model
Referenzdesigns

TIDA-010030 — Präzise Messung und Referenzdesign für Li-Ionen-Akkupack mit 50-μA-Standby-Strom, 13 Zellen und 48 V

This reference design is a low standby and ship mode current consumption and high SOC gauging accuracy 13S, 48-V Li-ion battery pack design. It monitors each cell voltage, pack current and temperature with high accuracy and protects the Li-ion battery pack against overvoltage, undervoltage, over (...)
Design guide: PDF
Schaltplan: PDF
Referenzdesigns

TIDA-010253 — Battery control unit reference design for energy storage systems

This reference design is a central controller for a high-voltage Lithium-ion (Li-ion), lithium iron phosphate (LiFePO4) battery rack. This design provides driving circuits for high-voltage relay, communication interfaces, (including RS-485, controller area network (CAN), daisy chain, and Ethernet), (...)
Design guide: PDF
Referenzdesigns

TIDA-010247 — Referenzdesign für High-Side-N-MOSFET-Steuerung (bis zu 32s)-Akkupack mit gestapeltem Batteriemonito

Dieses Referenzdesign ist ein Akkupack mit High-Side-MOSFET-N-Channel-Steuerung (bis zu 32s) und verwendet die gestapelte BQ769x2-Batteriemonitorfamilie. Dieses Design überwacht die Spannung, den Akkustrom sowie die Temperatur jeder Zelle und jedes MOSFET und schützt den Akkupack, damit er vom (...)
Design guide: PDF
Referenzdesigns

TIDA-010216 — Akkupack-Referenzdesign für 16 serielle Zellen mit Low-Side-MOSFET-Steuerung für Anwendungen mit gro

Bei diesem Referenzdesign handelt es sich um ein Lithium-Ionen (Li-Ion), LiFePO4‑Akkupack mit niedrigem Stromverbrauch im Standby- und Transport-Modus und hoher Zellspannungsgenauigkeit für 16 serielle Zellen. Das Design überwacht jede Zellenspannung, den Akkustrom, die Zell- und MOSFET-Temperatur (...)
Design guide: PDF
Gehäuse Pins CAD-Symbole, Footprints und 3D-Modelle
SOIC (DW) 16 Ultra Librarian
SOIC (DWV) 8 Ultra Librarian

Bestellen & Qualität

Beinhaltete Information:
  • RoHS
  • REACH
  • Bausteinkennzeichnung
  • Blei-Finish/Ball-Material
  • MSL-Rating / Spitzenrückfluss
  • MTBF-/FIT-Schätzungen
  • Materialinhalt
  • Qualifikationszusammenfassung
  • Kontinuierliches Zuverlässigkeitsmonitoring
Beinhaltete Information:
  • Werksstandort
  • Montagestandort

Empfohlene Produkte können Parameter, Evaluierungsmodule oder Referenzdesigns zu diesem TI-Produkt beinhalten.

Support und Schulungen

TI E2E™-Foren mit technischem Support von TI-Ingenieuren

Inhalte werden ohne Gewähr von TI und der Community bereitgestellt. Sie stellen keine Spezifikationen von TI dar. Siehe Nutzungsbedingungen.

Bei Fragen zu den Themen Qualität, Gehäuse oder Bestellung von TI-Produkten siehe TI-Support. ​​​​​​​​​​​​​​

Videos