SBASAL0A August 2025 – October 2025 ADC34RF72
PRODUCTION DATA
The analog inputs of the ADC34RF72 have internal buffers which isolate the sampling capacitor from the external input circuitry. The analog inputs have a programmable, differential split termination with internal biasing as shown in Figure 7-1. The differential termination can be selected to differential 50Ω, 100Ω or 200Ω via SPI register write. Both AC-coupling and DC-coupling of the analog inputs is supported.
The following parameters can be programmed:
|
System Parameter Name | Size (bits) | Default | Reset | Description |
|---|---|---|---|---|
| ADC{x}_INPUT_TERM_SEL | 2 | 0 | R/W | Select ADC{x} input termination setting (x = {0,1,2,3}) 0: 50Ω differential 1: 100Ω differential 2: 200Ω differential |