Following are comparison measurements of the different operating modes for the same input signal configuration.

| FIN = 125MHz, AIN = -1dBFS,
SNRflat = 74.8dBFS |
Figure 7-39 Single tone FFT, Normal Mode
| FIN = 125MHz, AIN = -1dBFS,
SNRflat = 77.5dBFS |
Figure 7-41 Single tone FFT, 2x Average Mode
| FIN = 125MHz, AIN = -1dBFS,
SNRflat = 80.2dBFS |
Figure 7-43 Single tone FFT, 4x Average Mode
| FIN = 125MHz, AIN = -20dBFS,
SNRflat = 75.5dBFS |
Figure 7-40 Single tone FFT, Normal Mode
| FIN = 200MHz, AIN = -20dBFS,
SNRflat = 78.2dBFS |
Figure 7-42 Single tone FFT, 2x Average Mode
| FIN = 200MHz, AIN = -20dBFS,
SNRflat = 80.6dBFS |
Figure 7-44 Single tone FFT , 4x Average Mode