SCLS569C January   2004  – April 2024 CD74HCT4051-Q1

PRODUCTION DATA  

  1.   1
  2. 1Features
  3. 2Applications
  4. 3Description
  5. 4Pin Configuration and Functions
  6. 5Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 Recommended Operating Conditions
    3. 5.3 Electrical Characteristics: HCT Devices
    4. 5.4 Switching Characteristics
    5. 5.5 Analog Channel Specifications
    6. 5.6 Typical Characteristics
  7. 6Parameter Measurement Information
  8. 7Device and Documentation Support
    1. 7.1 Documentation Support
      1. 7.1.1 Related Documentation
    2. 7.2 Receiving Notification of Documentation Updates
    3. 7.3 Support Resources
    4. 7.4 Trademarks
    5. 7.5 Electrostatic Discharge Caution
    6. 7.6 Glossary
  9. 8Revision History
  10. 9Mechanical, Packaging, and Orderable Information

Package Options

Refer to the PDF data sheet for device specific package drawings

Mechanical Data (Package|Pins)
  • D|16
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Switching Characteristics

over operating free-air temperature range (unless otherwise noted)
Parameter Test Conditions MIN NOM MAX UNIT
tPD
Switch IN to OUT

 
CL = 15pF VCC = 5V 25°C 4 ns
CL = 50pF VCC = 4.5V 25°C 12 ns
–40°C to +125°C 18 ns
VCC = 4.5V,  VEE = -4.5V 25°C 8 ns
–40°C to +125°C 12 ns
ten ADDRESS SEL or E to OUT CL = 15pF VCC = 5V 25°C 23 ns
CL = 50pF VCC = 4.5V 25°C 55 ns
–40°C to +125°C 83 ns
VCC = 4.5V,  VEE = -4.5V 25°C 48 ns
–40°C to +125°C 60 ns
tdis ADDRESS SEL or E to OUT CL = 15pF VCC = 5V 25°C 35 ns
CL = 50pF VCC = 4.5V 25°C 50 ns
–40°C to +125°C 68 ns
VCC = 4.5V,  VEE = -4.5V 25°C 44 ns
–40°C to +125°C 55 ns
CI Control –40°C to +125°C 10 pF
CPD Power dissipation capacitance (1) 52 pF
Cpd is used to determine the dynamic power consumption, per package.
PD = Cpd VCC2 fI + Σ (CL + CS) VCC2 fO
fO = output frequency
fI = input frequency
CL = output load capacitance
CS = switch capacitance
VCC = supply voltage