SLVSGS6 October 2023 – July 2026 DRV3901-Q1
PRODUCTION DATA
From the STANDBY state, the device can be commanded to perform off-state diagnostics with a valid SPI command. The diagnostics include a series of sequenced, self-timed tests that check the availability of the deployment function without creating a risk of inadvertent deployment.
Failure in any of the first six tests results in aborting the off-state diagnostics at the instant of the failure. Off-state diagnostics function is not available in case of VDRV undervoltage, VDRV overvoltage warning, or over temperature warning. The results are captured in the STATUS registers, OFF_DIAG_STAT and OFF_DIAG_SUM.
At any time during off-state diagnostics, the device can accept a valid pin TRG or SPI command to deploy. At this point, the device aborts the diagnostics instantly in controlled manner and transition to ACTIVE state for deployment. The deployment delay parameters tDLY0 and tDLY1 times are still maintained.
The sequence of tests and their objective is as follows:
The sequence of the tests cannot be changed, but individual tests can be disabled through the CONFIG registers.
During device operation, the following 3 combinations are recommended to conduct the off-state diagnostics: