  7. Specifications
    1. 7.1 Absolute Maximum Ratings
    2. 7.2 ESD Ratings
    3. 7.3 Recommended Operating Conditions
    4. 7.4 Thermal Information
    5. 7.5 Electrical Characteristics
    6. 7.6 Magnetic Characteristics
    7. 7.7 Typical Characteristics
  8. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 Magnetic Flux Direction
      2. 8.3.2 Device Version Comparison
        1. 8.3.2.1 Magnetic Threshold
        2. 8.3.2.2 Magnetic Response
        3. 8.3.2.3 Output Type
        4. 8.3.2.4 Sampling Rate
      3. 8.3.3 Hall Element Location
    4. 8.4 Device Functional Modes
  9. Application and Implementation
    1. 9.1 Application Information
      1. 9.1.1 Output Type Tradeoffs
    2. 9.2 Typical Applications
      1. 9.2.1 General-Purpose Magnet Sensing
        1. 9.2.1.1 Design Requirements
        2. 9.2.1.2 Detailed Design Procedure
        3. 9.2.1.3 Application Curve
      2. 9.2.2 Three-Position Switch
        1. 9.2.2.1 Design Requirements
        2. 9.2.2.2 Detailed Design Procedure
        3. 9.2.2.3 Application Curve
    3. 9.3 Do's and Don'ts
  10. 10Power Supply Recommendations
  11. 11Layout
    1. 11.1 Layout Guidelines
    2. 11.2 Layout Examples
  12. 12Device and Documentation Support
    1. 12.1 Documentation Support
      1. 12.1.1 Related Documentation
    2. 12.2 Receiving Notification of Documentation Updates
    3. 12.3 Support Resources
    4. 12.4 Trademarks
    5. 12.5 Electrostatic Discharge Caution
    6. 12.6 Glossary
  13. 13Mechanical, Packaging, and Orderable Information

Package Options

Refer to the PDF data sheet for device specific package drawings

Mechanical Data (Package|Pins)
  • DBZ|3
  • DMR|4
  • LPG|3
Thermal pad, mechanical data (Package|Pins)
Orderable Information

Magnetic Characteristics

for VCC = 1.65 V to 5.5 V, over operating free-air temperature range (unless otherwise noted)(1)
PARAMETERTEST CONDITIONSMINTYPMAXUNIT
DU VERSION
BOPMagnetic threshold operate pointOUT1 pin (north)(2)–3.9–2.5–1.2mT
OUT2 pin (south)1.22.53.9
BRPMagnetic threshold release pointOUT1 pin (north)(2)–3.5–1.8–0.9mT
OUT2 pin (south)0.91.83.5
BHYSMagnetic hysteresis: |BOP – BRP|Each output0.10.71.9mT
FA, FB, FC VERSIONS
BOPMagnetic threshold operate point±1.5±3±4.8mT
BRPMagnetic threshold release point±0.5±1.5±3mT
BHYSMagnetic hysteresis: |BOP – BRP|0.81.53mT
FD VERSION
BOPMagnetic threshold operate pointOUT1 pin (north)(2)–4.8–3–1.5mT
OUT2 pin (south)1.534.8
BRPMagnetic threshold release pointOUT1 pin (north)(2)–3–1.5–0.5mT
OUT2 pin (south)0.51.53
BHYSMagnetic hysteresis: |BOP – BRP|Each output0.81.53mT
AJ VERSION
BOPMagnetic threshold operate point±4±7±9.5mT
BRPMagnetic threshold release point±3±5.6±7.5mT
BHYSMagnetic hysteresis: |BOP – BRP|0.51.43mT
ZE VERSION
BOPMagnetic threshold operate point±33±47±63mT
BRPMagnetic threshold release point±30±43±58mT
BHYSMagnetic hysteresis: |BOP – BRP|1.248.5mT
For a graphical description of magnetic thresholds, see the Section 8.3.2.2 section.
X2SON package only.