4 Revision History
Changes from Revision * (December 2021) to Revision A (February 2023)
- Changed standard name From: "DIN V VDE V 0884-11:2017-01" To: "DIN
EN IEC 60747-17 (VDE 0884-17)" throughout the document Go
- Removed references to standard IEC/EN/CSA 60950-1 throughout the
documentGo
- Updated standards marked as "planned" to include certificate
numbers thoughout the documentGo
- Removed standard revision and year references from all standard
names thoughout the documentGo
- Added Maximum impulse voltage (VIMP) specification per DIN EN IEC 60747-17 (VDE 0884-17)Go
- Changed test conditions and values of Maximum surge isolation voltage (VIOSM) specification per DIN EN IEC 60747-17 (VDE 0884-17)Go
- Clarified method b test conditions of Apparent charge (qPD)Go
- Changed Maximum surge isolation voltage (VIOSM) from 6250 VPK to 10000 VPK
Go
- Changed working voltage lifetime margin From: 87.5% To: 50%, minimum
required insulation lifetime From: 37.5 years To: 30 years and insulation lifetime per
TDDB From: 220 years To: 36 years per DIN EN IEC 60747-17 (VDE 0884-17)Go
- Changed Figure 10-2 as per DIN EN IEC 60747-17 (VDE 0884-17)Go
- Updated to DW0016B mechanical drawingGo