SLLSFJ3C February   2021  – December 2021 TCAN1044A-Q1 , TCAN1044AV-Q1

PRODUCTION DATA  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Device Comparison
  6. Pin Configuration and Functions
  7. Specifications
    1. 7.1  Absolute Maximum Ratings
    2. 7.2  ESD Ratings
    3. 7.3  ESD Ratings - IEC Specifications
    4. 7.4  Recommended Operating Conditions
    5. 7.5  Thermal Characteristics
    6. 7.6  Supply Characteristics
    7. 7.7  Dissipation Ratings
    8. 7.8  Electrical Characteristics
    9. 7.9  Switching Characteristics
    10. 7.10 Typical Characteristics
  8. Parameter Measurement Information
  9. Detailed Description
    1. 9.1 Overview
    2. 9.2 Functional Block Diagram
    3. 9.3 Feature Description
      1. 9.3.1 Pin Description
        1. 9.3.1.1 TXD
        2. 9.3.1.2 GND
        3. 9.3.1.3 VCC
        4. 9.3.1.4 RXD
        5. 9.3.1.5 VIO
        6. 9.3.1.6 CANH and CANL
        7. 9.3.1.7 STB (Standby)
      2. 9.3.2 CAN Bus States
      3. 9.3.3 TXD Dominant Timeout (DTO)
      4. 9.3.4 CAN Bus short-circuit current limiting
      5. 9.3.5 Thermal Shutdown (TSD)
      6. 9.3.6 Undervoltage Lockout
      7. 9.3.7 Unpowered Device
      8. 9.3.8 Floating pins
    4. 9.4 Device Functional Modes
      1. 9.4.1 Operating Modes
      2. 9.4.2 Normal Mode
      3. 9.4.3 Standby Mode
        1. 9.4.3.1 Remote Wake Request via Wake-Up Pattern (WUP) in Standby Mode
      4. 9.4.4 Driver and Receiver Function
  10. 10Application Information Disclaimer
    1. 10.1 Application Information
    2. 10.2 Typical Application
      1. 10.2.1 Design Requirements
        1. 10.2.1.1 CAN Termination
      2. 10.2.2 Detailed Design Procedures
        1. 10.2.2.1 Bus Loading, Length and Number of Nodes
    3. 10.3 System Examples
  11. 11Power Supply Recommendations
  12. 12Layout
    1. 12.1 Layout Guidelines
    2. 12.2 Layout Example
  13. 13Device and Documentation Support
    1. 13.1 Receiving Notification of Documentation Updates
    2. 13.2 Support Resources
    3. 13.3 Trademarks
    4. 13.4 Electrostatic Discharge Caution
    5. 13.5 Glossary

Package Options

Mechanical Data (Package|Pins)
Thermal pad, mechanical data (Package|Pins)
Orderable Information

CAN Termination

Termination may be a single 120-Ω resistor at each end of the bus, either on the cable or in a terminating node. If filtering and stabilization of the common-mode voltage of the bus is desired then split termination may be used, see Figure 10-2. Split termination improves the electromagnetic emissions behavior of the network by filtering higher-frequency common-mode noise that may be present on the differential signal lines.

GUID-403B33B2-0E5F-4009-85F5-CAB60C277AEB-low.gifFigure 10-2 CAN Bus Termination Concepts