SLVSH18B December 2024 – July 2025 TPS4HC120-Q1
PRODUCTION DATA
Refer to the PDF data sheet for device specific package drawings
| PIN | TYPE | DESCRIPTION | |
|---|---|---|---|
| NO. | NAME | ||
| 1, 14, 19, 24 | NC | N/A | No internal connection. |
| 2 | EN1 | Input | Input control for channel 1 activation, internal pulldown. |
| 3 | EN2 | Input | Input control for channel 2 activation, internal pulldown. |
| 4 | EN3 | Input | Input control for channel 3 activation, internal pulldown. |
| 5 | EN4 | Input | Input control for channel 4 activation, internal pulldown. |
| 6 | SEL1 | Input | SNS channel-selection high bit; internal pulldown. |
| 7 | SEL0 | Input | SNS channel-selection low bit; internal pulldown. |
| 8 | DIAG_EN | Input | Enable-disable pin for diagnostics, internal pulldown. |
| 9 | FLT | Output | Open drain global fault output. Referred to FAULT, FLT, or fault pin. Recommended 5kΩ–10kΩ pullup resistor. |
| 10 | LPM | Output | Open drain LPM status pin. Pulled high by external supply if the device is in LPM or SLEEP state. Pulled low internally when device is in ACTIVE mode. Recommended 5kΩ–10kΩ pullup resistor. |
| 11 | SNS | Output | SNS current output. |
| 12 | ILIM | Output | Adjustable current limit. Connect a resistor to chip GND, SHORT the pin to chip GND, or leave the pin OPEN to set the current limit value. |
| 13 | GND | Power | Ground of device. Connect to resistor- diode ground network to have reverse battery protection. |
| 15, 16 | VOUT4 | Power | Output of channel 4 of the high side switch, connected to load. |
| 17, 18 | VOUT3 | Power | Output of channel 3 of the high side switch, connected to load. |
| 20, 21, 22, 23 | VBB | Power | Power supply |
| 25, 26 | VOUT2 | Power | Output of channel 2 of the high side switch, connected to load. |
| 27, 28 | VOUT1 | Power | Output of channel 1 of the high side switch, connected to load. |
| Thermal Pad | Pad | Power | Thermal Pad, internally shorted to ground. |