SLVSIA8 October 2026 TPSM846C26
PRODUCTION DATA
| CMD Address | 09h |
| Write Transaction: | Write Block |
| Read Transaction: | N/A |
| Format: | Varies (Target Command + 3 bytes) |
| Phased: | No |
| NVM Back-up: | No |
| Updates: | On-the-fly |
The P2_PLUS_WRITE command allows a user to send a command and associated data to a device (or devices) in a multi-phase stack in a single transaction using only the common address of the primary device. This action does not alter the value of the PHASE command of the addressed device after the P2_PLUS_WRITE command is completed.
P2_PLUS_WRITE uses a Block Write format with 3 additional bytes beyond the data of the base command. 1 byte for PAGE, 1 byte for PHASE, and 1 byte for the target command to be written. The full command structure is:
[TARGET ADDRESS] + [P2_PLUS_WRITE] + [BLOCK COUNT] + [PAGE] + [PHASE] + [COMMAND] + [DATA]
| TARGET ADDRESS | P2_PLUS_WRITE | BLOCK COUNT | PAGE | PHASE | COMMAND | DATA |
|---|---|---|---|---|---|---|
| Primary Device Address | 09h | Data type to write: Byte: 04h Word: 05h Block: Block Size + 3h |
00h or FFh | 00h: Primary 01h: Secondary 1 02h: Secondary 2 03h: Secondary 3 FFh: All Phases |
Command to write | Data to write |
The PHASE setting can be set to the unique phase determined by STACK_POSITION in STACK_CONFIG (PHASE = 00h to 03h) or all phases (PHASE = FFh). Since the TPSM846C26 does not support multipe pages, the only accepted values for PAGE are 00h or FFh (which are treated the same). For any PHASE or PAGE setting outside of the valid range, the device sets the IVC bit and asserts SMBALERT#.
When sending multiple bytes of data, data must be sent in order of lowest to highest byte. Examples include:
The BLOCK_COUNT field encompases the full byte length of the PAGE, PHASE, COMMAND, & DATA fields and will vary based on data frame length.
For additional details and examples, consult the PMBus® specification entry for P2_PLUS_WRITE (PMBus Part II Rev 1.5 Section 11.17 Pages 71-73).
Note that secondary devices do not support read/writes to all commands (see Supported PMBus Commands).
Return to Supported PMBus Commands.
| 23 | 22 | 21 | 20 | 19 | 18 | 17 | 16 |
| W | W | W | W | W | W | W | W |
| P2_PLUS_WR_CMD | |||||||
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
| W | W | W | W | W | W | W | W |
| P2_PLUS_WR_PHASE_NUM | |||||||
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| W | W | W | W | W | W | W | W |
| P2_PLUS_WR_PAGE_NUM | |||||||
| LEGEND: R/W = Read/Write; R = Read only |
| Bit | Field | Access | Reset | Description |
|---|---|---|---|---|
| 23:16 | P2_PLUS_WR_CMD | W | 00000000b | |
| 15:8 | P2_PLUS_WR_PHASE_NUM | W | 00000000b | |
| 7:0 | P2_PLUS_WR_PAGE_NUM | W | 00000000b |