6.5.1 Use The Following Procedure to Write to TUSB1044 I2C Registers:
The master initiates a write operation by generating a start condition (S), followed by the TUSB1044 7-bit address and a zero-value “W/R” bit to indicate a write cycle .
The TUSB1044 acknowledges the address cycle.
The master presents the sub-address (I2C register within TUSB10444) to be written, consisting of one byte of data, MSB-first.
The TUSB1044 acknowledges the sub-address cycle.
The master presents the first byte of data to be written to the I2C register.
The TUSB1044 acknowledges the byte transfer.
The master may continue presenting additional bytes of data to be written, with each byte transfer completing with an acknowledge from the TUSB1044.
The master terminates the write operation by generating a stop condition (P).