JAJSGE0C JANUARY 2014 – October 2018 TPS40425
PRODUCTION DATA.
| Format | N/A | ||||
| Description | The PMBus spec dictates that the data word for the VOUT_MODE command is one byte that consists of a 3-bit Mode and 5-bit parameter, as shown below.
If a host sends a VOUT_MODE command for a write to TPS40425, the device rejects the VOUT_MODE command, declare a communication fault for invalid data and respond as described in PMBus specification II section 10.2.2. |
||||
| Default | 00010111 (binary) | ||||
| r | r | r | r | r | r | r | r |
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| Mode | Exponent | ||||||
| Bits | Field Name | Description |
|---|---|---|
| 7:5 | Mode | (Format: binary)
000: (Default) Linear Format |
| 4:0 | Exponent | (Format: two's complement binary)
10111: (Default) Exponent value = –9 Note: Any values written to read-only registers are ignored. |