JAJSGE0C JANUARY 2014 – October 2018 TPS40425
PRODUCTION DATA.
| Format | Unsigned binary | ||||
| Description | The STATUS_ MFR_SPECIFIC command returns one byte containing manufacturer-specific faults or warnings. | ||||
| Default | 00000000 (binary) | ||||
| read only | |||||||
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| otfi | x | x | ivaddr | ch1_sps_flt | ch2_sps_flt | ch1_slave | ch2_slave |
| Bits | Field Name | Description |
|---|---|---|
| 7 | otfi | (Format: binary)
Over temperature fault internal. This bit is required to distinguish an over temperature fault internal to TPS40425 from an external temperature fault. 0: (Default) The internal temperature is below the fault threshold. 1: The internal temperature is above the fault threshold. |
| 6:5 | x | Default: 0 |
| 4 | ivaddr | (Format: binary)
Invalid PMBus address This bit is set when the PMBus address detection circuit does not resolve to a valid address. In this event, the device responds to the address: 127d. 0: (Default) |
| 3 | ch1_sps_flt | (Format: binary)
Channel 1 smart power-stage fault This bit reports that the smart power-stage has declared a fault (either over-current or over-temperature) on the TSNS1 pin of TPS40425. 0: (Default) |
| 2 | ch2_sps_flt | (Format: binary)
Channel 2 smart power-stage fault This bit reports that the smart power-stage has declared a fault (either over-current or over-temperature) on the TSNS2 pin of TPS40425. 0: (Default) |
| 1 | ch1_slave | (Format: binary)
Channel 1 Slave This bit is set when channel 1 is configured as a slave channel (by pulling FB1 > 2.5 V before power-up). It is only used for internal read purposes and does not trigger SMBLERT. 0: (Default) |
| 0 | ch2_slave | (Format: binary)
Channel 2 Slave This bit is set when channel 2 is configured as a slave channel (by pulling FB2 > 2.5 V before power-up). It is only used for internal read purposes and does not trigger SMBLERT. 0: (Default) |