JAJSGE0C JANUARY 2014 – October 2018 TPS40425
PRODUCTION DATA.
| Format | Linear | ||||
| Description | The READ_TEMPERATURE_2 command returns the temperature in degrees Celsius of the current channel specified by the PAGE command. | ||||
| Default | F064h | ||||
| PAGE0, PAGE1 | |||||||||||||||
| r | r | r | r | r | r | r | r | r | r | r | v | r | r | r | r |
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| Exponent | Mantissa | ||||||||||||||
| Bits | Field Name | Description |
|---|---|---|
| 7:3 | Exponent | (Format: two's complement)
This is the exponent for the linear format. Default: 11110 (bin) –2 (dec) 0.25°C These default settings are not programmable. Note: Any values written to read-only registers are ignored. |
| 2:0
7:0 |
Mantissa | (Format: two's complement)
Default: 000 0110 0100 (bin) 100 (dec) Note: Any values written to read-only registers are ignored. |