JAJSFE6I July   2009  – May 2018 TPS65070 , TPS65072 , TPS65073 , TPS650731 , TPS650732

UNLESS OTHERWISE NOTED, this document contains PRODUCTION DATA.  

  1. 特長
  2. アプリケーション
  3. 概要
    1.     ブロック図
  4. 改訂履歴
  5. 概要(続き)
  6. Device Options
  7. Pin Configuration and Functions
    1.     Pin Functions
  8. Specifications
    1. 8.1  Absolute Maximum Ratings
    2. 8.2  ESD Ratings
    3. 8.3  Recommended Operating Conditions
    4. 8.4  Thermal Information
    5. 8.5  Electrical Characteristics
    6. 8.6  Electrical Characteristics - DCDC1 Converter
    7. 8.7  Electrical Characteristics - DCDC2 Converter
    8. 8.8  Electrical Characteristics - DCDC3 Converter
    9. 8.9  Electrical Characteristics - VLDO1 and VLDO2 Low Dropout Regulators
    10. 8.10 Electrical Characteristics - wLED Boost Converter
    11. 8.11 Electrical Characteristics - Reset, PB_IN, PB_OUT, PGood, Power_on, INT, EN_EXTLDO, EN_wLED
    12. 8.12 Electrical Characteristics - ADC Converter
    13. 8.13 Electrical Characteristics - Touch Screen Interface
    14. 8.14 Electrical Characteristics - Power Path
    15. 8.15 Electrical Characteristics - Battery Charger
    16. 8.16 Timing Requirements
    17. 8.17 Dissipation Ratings
    18. 8.18 Typical Characteristics
  9. Parameter Measurement Information
  10. 10Detailed Description
    1. 10.1 Overview
    2. 10.2 Functional Block Diagram
    3. 10.3 Feature Description
      1. 10.3.1  Battery Charger and Power Path
      2. 10.3.2  Power Down
      3. 10.3.3  Power-On Reset
      4. 10.3.4  Power-Path Management
        1. 10.3.4.1 SYS Output
      5. 10.3.5  Battery Charging
        1. 10.3.5.1 I-PRECHARGE
        2. 10.3.5.2 ITERM
        3. 10.3.5.3 Battery Detection and Recharge
        4. 10.3.5.4 Charge Termination On/Off
        5. 10.3.5.5 Timers
        6. 10.3.5.6 Dynamic Timer Function
        7. 10.3.5.7 Timer Fault
      6. 10.3.6  Battery Pack Temperature Monitoring
      7. 10.3.7  Battery Charger State Diagram
      8. 10.3.8  DC-DC Converters and LDOs
        1. 10.3.8.1 Operation
        2. 10.3.8.2 DCDC1 Converter
        3. 10.3.8.3 DCDC2 Converter
        4. 10.3.8.4 DCDC3 Converter
      9. 10.3.9  Power Save Mode
        1. 10.3.9.1 Dynamic Voltage Positioning
        2. 10.3.9.2 100% Duty Cycle Low Dropout Operation
        3. 10.3.9.3 Undervoltage Lockout
      10. 10.3.10 Short-Circuit Protection
        1. 10.3.10.1 Soft Start
      11. 10.3.11 Enable
        1. 10.3.11.1 RESET (TPS65070, TPS65073, TPS650731, TPS650732 Only)
        2. 10.3.11.2 PGOOD (Reset Signal For Applications Processor)
        3. 10.3.11.3 PB_IN (Push-Button IN)
        4. 10.3.11.4 PB_OUT
        5. 10.3.11.5 POWER_ON
        6. 10.3.11.6 EN_wLED (TPS65072 Only)
        7. 10.3.11.7 EN_EXTLDO (TPS65072 Only)
      12. 10.3.12 Short-Circuit Protection
      13. 10.3.13 Thermal Shutdown
        1. 10.3.13.1 Low Dropout Voltage Regulators
        2. 10.3.13.2 White LED Boost Converter
        3. 10.3.13.3 A/D Converter
        4. 10.3.13.4 Touch Screen Interface (only for TPS65070, TPS65073, TPS650731, TPS650732)
          1. 10.3.13.4.1 Performing Measurements Using the Touch Screen Controller
    4. 10.4 Device Functional Modes
    5. 10.5 Programming
      1. 10.5.1 I2C Interface Specification
        1. 10.5.1.1 Serial interface
    6. 10.6 Register Maps
      1. 10.6.1  PPATH1. Register Address: 01h
      2. 10.6.2  INT. Register Address: 02h
      3. 10.6.3  CHGCONFIG0. Register Address: 03h
      4. 10.6.4  CHGCONFIG1. Register Address: 04h
      5. 10.6.5  CHGCONFIG2. Register Address: 05h
      6. 10.6.6  CHGCONFIG3. Register Address: 06h
      7. 10.6.7  ADCONFIG. Register Address: 07h
      8. 10.6.8  TSCMODE. Register Address: 08h
      9. 10.6.9  ADRESULT_1. Register Address: 09h
      10. 10.6.10 ADRESULT_2. Register Address: 0Ah
      11. 10.6.11 PGOOD. Register Address: 0Bh
      12. 10.6.12 PGOODMASK. Register Address: 0Ch
      13. 10.6.13 CON_CTRL1. Register Address: 0Dh
      14. 10.6.14 CON_CTRL2. Register Address: 0Eh
      15. 10.6.15 CON_CTRL3. Register Address: 0Fh
      16. 10.6.16 DEFDCDC1. Register Address: 10h
      17. 10.6.17 DEFDCDC2_LOW. Register Address: 11h
      18. 10.6.18 DEFDCDC2_HIGH. Register Address: 12h
      19. 10.6.19 DEFDCDC3_LOW. Register Address: 13h
      20. 10.6.20 DEFDCDC3_HIGH. Register Address: 14h
      21. 10.6.21 DEFSLEW. Register Address: 15h
      22. 10.6.22 LDO_CTRL1. Register Address: 16h
      23. 10.6.23 DEFLDO2. Register Address: 17h
      24. 10.6.24 WLED_CTRL1. Register Address: 18h
      25. 10.6.25 WLED_CTRL2. Register Address: 19h
  11. 11Application and Implementation
    1. 11.1 Application Information
      1. 11.1.1 Power Solutions For Different Application Processors
        1. 11.1.1.1 Default Settings
        2. 11.1.1.2 Starting TPS6507x
    2. 11.2 Typical Applications
      1. 11.2.1 General PMIC Application
        1. 11.2.1.1 Design Requirements
        2. 11.2.1.2 Detailed Design Procedure
          1. 11.2.1.2.1 Output Filter Design (Inductor and Output Capacitor)
            1. 11.2.1.2.1.1 Inductor Selection
            2. 11.2.1.2.1.2 Output Capacitor Selection
            3. 11.2.1.2.1.3 Input Capacitor Selection/Input Voltage
            4. 11.2.1.2.1.4 Output Voltage Selection
            5. 11.2.1.2.1.5 Voltage Change on DCDC2 and DCDC3
          2. 11.2.1.2.2 LDOs
            1. 11.2.1.2.2.1 Output Capacitor Selection
            2. 11.2.1.2.2.2 Input Capacitor Selection
            3. 11.2.1.2.2.3 Output Voltage Change For LDO1 and LDO2
            4. 11.2.1.2.2.4 Unused LDOs
          3. 11.2.1.2.3 White-LED Boost Converter
            1. 11.2.1.2.3.1 LED-Current Setting/Dimming
            2. 11.2.1.2.3.2 Setup
            3. 11.2.1.2.3.3 Setting the LED Current
            4. 11.2.1.2.3.4 Inductor Selection
            5. 11.2.1.2.3.5 Diode Selection
            6. 11.2.1.2.3.6 Output Capacitor Selection
            7. 11.2.1.2.3.7 Input Capacitor Selection
          4. 11.2.1.2.4 Battery Charger
            1. 11.2.1.2.4.1 Temperature Sensing
            2. 11.2.1.2.4.2 Changing the Charging Temperature Range (Default 0°C to 45°C)
        3. 11.2.1.3 Application Curves
      2. 11.2.2 Powering OMAP-L138
        1. 11.2.2.1 Design Requirements
        2. 11.2.2.2 Detailed Design Procedure
      3. 11.2.3 Powering Atlas IV
        1. 11.2.3.1 Design Requirements
        2. 11.2.3.2 Detailed Design Procedure
          1. 11.2.3.2.1 Prima SLEEP Mode and DEEP SLEEP Mode Support
          2. 11.2.3.2.2 SLEEP Mode
          3. 11.2.3.2.3 DEEP SLEEP Mode
      4. 11.2.4 OMAP35xx (Supporting SYS-OFF Mode)
        1. 11.2.4.1 Design Requirements
        2. 11.2.4.2 Detailed Design Procedure
      5. 11.2.5 TPS650731 for OMAP35xx
        1. 11.2.5.1 Design Requirements
        2. 11.2.5.2 Detailed Design Procedure
      6. 11.2.6 Powering AM3505 Using TPS650732
        1. 11.2.6.1 Design Requirements
        2. 11.2.6.2 Detailed Design Procedure
  12. 12Power Supply Recommendations
  13. 13Layout
    1. 13.1 Layout Guidelines
    2. 13.2 Layout Example
  14. 14デバイスおよびドキュメントのサポート
    1. 14.1 デバイス・サポート
      1. 14.1.1 デベロッパー・ネットワークの製品に関する免責事項
    2. 14.2 ドキュメントのサポート
      1. 14.2.1 関連資料
    3. 14.3 関連リンク
    4. 14.4 ドキュメントの更新通知を受け取る方法
    5. 14.5 コミュニティ・リソース
    6. 14.6 商標
    7. 14.7 静電気放電に関する注意事項
    8. 14.8 Glossary
  15. 15メカニカル、パッケージ、および注文情報

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報

CHGCONFIG0. Register Address: 03h

CHGCONFIG0 B7 B6 B5 B4 B3 B2 B1 BO
Bit name and function Thermal regulation DPPM active Thermal Suspend Term Current Chg Timeout Prechg Timeout BatTemp error
Default x x x x 0 x x x
Set by signal
Default value loaded by: UVLO UVLO UVLO UVLO UVLO UVLO UVLO
Read/write R R R R R R R R
Bit 7 THERMAL REGULATION:
0 = charger is in normal operation
1 = charge current is reduced due to high chip temperature
Bit 6 DPPM ACTIVE:
0 = DPPM loop is not active
1 = DPPM loop is active; charge current is reduced to support the load with the current required
Bit 5 THERMAL SUSPEND:
0 = charging is allowed
1 = charging is momentarily suspended because battery temperature is out of range
Bit 4 TERM CURRENT:
0 = charge termination current threshold has not been crossed; charging or no voltage at AC and USB
1 = charge termination current threshold has been crossed and charging has been stopped. This can be due to a battery reaching full capacity or to a battery removal condition
Bit 2..Bit1 CHG TIMEOUT, PRECHG TIMEOUT
0 = charging, timers did not time out
1 = one of the timers has timed out and charging has been terminated
Bit 0 BAT TEMP ERROR:
0 = battery temperature is in the allowed range for charging
1 = no temperature sensor detected