JAJSW05A March 2020 – January 2025 BQ24800
PRODUCTION DATA
If no battery is present, hybrid boost mode has been disabled, or if the hybrid boost discharge current has been reached, the BQ24800 device cannot maintain the input current level once the charge current has been reduced to 0. When the input current exceeds 1.25x or 2x of ILIM2 set point for the 6-ms deglitch time, ACFET/RBFET is latched off and an adapter removal is required to force ACDET < 0.6 V to remove the latch. After the latch is removed, ACFET/RBFET can be turned on again.
The ACOC function threshold can be set to 1.25x or 2x of ICRIT (REG0x37[9]) current or disabled through SMBus command (REG0x37[10]).