SBVS324B June 2017 – September 2026 TPS7A90
PRODUCTION DATA
Output voltage accuracy specifies minimum and maximum output voltage error, relative to the expected nominal output voltage stated as a percent. The TPS7A90 features an output voltage accuracy of 1% that includes the errors introduced by the internal reference, load regulation, and line regulation variance across the full range of rated load and line operating conditions overtemperature, as Electrical Characteristics specifies. Output voltage accuracy also accounts for all variations between manufacturing lots.