SCES987A
June 2025 – September 2025
TXG4041
,
TXG4042
PRODUCTION DATA
1
1
Features
2
Applications
3
Description
4
Pin Configuration and Functions
5
Specifications
5.1
Absolute Maximum Ratings
5.2
ESD Ratings
5.3
Recommended Operating Conditions
5.4
Thermal Information
5.5
Electrical Characteristics
5.6
Supply Current
5.7
Switching Characteristics, VCCA = 1.8 ± 0.15V
5.8
Switching Characteristics, VCCA = 2.5 ± 0.2V
5.9
Switching Characteristics, VCCA = 3.3 ± 0.3V
5.10
Switching Characteristics, VCCA = 5.0 ± 0.5V
5.11
Switching Characteristics: Tsk, TMAX
5.12
Typical Characteristics
6
Parameter Measurement Information
6.1
Load Circuit and Voltage Waveforms
7
Detailed Description
7.1
Overview
7.2
Functional Block Diagram
7.3
Feature Description
7.3.1
CMOS Schmitt-Trigger Inputs with Integrated Pulldowns
7.3.1.1
Inputs with Integrated Static Pull-Down Resistors
7.3.2
Balanced High-Drive CMOS Push-Pull Outputs
7.3.3
VCC Disconnect
7.3.4
Over-Voltage Tolerant Inputs
7.3.5
Glitch-Free Power Supply Sequencing
7.3.6
Negative Clamping Diodes
7.3.7
Fully Configurable Dual-Rail Design
7.3.8
Supports High-Speed Translation
7.3.9
AC Noise Rejection
7.4
Device Functional Modes
8
Application and Implementation
8.1
Application Information
8.2
Typical Application
8.2.1
Design Requirements
8.2.2
Detailed Design Procedure
8.2.3
Application Curve
8.3
Power Supply Recommendations
8.4
Layout
8.4.1
Layout Guidelines
8.4.2
Layout Example
9
Device and Documentation Support
9.1
Documentation Support
9.1.1
Related Documentation
9.2
Receiving Notification of Documentation Updates
9.3
Support Resources
9.4
Trademarks
9.5
Electrostatic Discharge Caution
9.6
Glossary
10
Revision History
11
Mechanical, Packaging, and Orderable Information
5.2
ESD Ratings
VALUE
UNIT
V
(ESD)
Electrostatic discharge
Human body model (HBM), per ANSI/ESDA/JEDEC JS-001
(1)
±4000
V
Charged device model (CDM), per ANSI/ESDA/JEDEC JS-002
(2)
±500
(1)
JEDEC document JEP155 states that 500V HBM allows safe manufacturing with a standard ESD control process.
(2)
JEDEC document JEP157 states that 250V CDM allows safe manufacturing with a standard ESD control process.