SDAA373 August   2026 LM51770

 

  1.   1
  2.   Abstract
  3.   Trademarks
  4. 1Introduction
  5. 2Automotive LED Application Requirements and System Overview
    1. 2.1 Application Requirements
    2. 2.2 Typical Automotive Headlight System Overview
    3. 2.3 LED Load Configuration and Switching Architecture
  6. 3LM51770-Q1 Pin Configuration for ILIM Function
    1. 3.1 LM51770-Q1 Pin Description
    2. 3.2 Pin Configuration for ILIM Operation
  7. 4Automotive LED Lighting Design Application
    1. 4.1 Power Stage Design
    2. 4.2 Control Loop Architecture
  8. 5ILIM Loop Optimization and Measurement Results
    1. 5.1 Strong Voltage Loop Compensation
    2. 5.2 Weak Voltage Loop Compensation
    3. 5.3 LED Switching and Buck-Boost Region
  9. 6Detailed Results
    1. 6.1 LED Steady State Operation Results
    2. 6.2 LED Switching State Operation Results
  10. 7Summary
  11. 8References

Control Loop Architecture

The LM51770 integrates three inherent control loops —one voltage loop and two current control loops (peak current limit and average current limit) — to regulate the output voltage and current to the desired set points. The interaction between these loops is illustrated in Figure 4-2.

  1. Voltage Control Loop: The voltage control loop continuously monitors the output voltage and compares it against an internal reference. The resulting error signal drives the error amplifier, which adjusts the COMP pin voltage to modulate the PWM duty cycle until the output voltage converges to the desired set point.
  2. Peak Current Limit Loop: The peak current limit loop measures the instantaneous inductor current and compares it against the COMP voltage generated by the voltage loop error amplifier. When the load current increases and the peak inductor current reaches the programmed maximum threshold — set by the current sense resistor RCS — the loop regulates the peak inductor current to that maximum value. Under these conditions, the voltage loop responds by raising the COMP voltage, which in turn reduces the PWM duty cycle and reduce the output voltage. While the peak current limit loop can be utilized for LED current control in certain applications, its inherent limitations in accuracy make it less suitable for precision LED drive applications where tight current regulation is required.The transfer function and control equations for the peak current mode control is well covered in the LM51770-Q1 datasheet and this Switch-mode power converter compensation made easy. Whereas, the important equations for the poles and zero for the type II compensation for the voltage control loop is given by the equation 3-4.
    Equation 3. F V _ p o l e ,   o r i g i n   =   0
    Frequency for the Pole on origin:Frequency for the Zero:
    Equation 4. F V _ z e r o   =   1 2 × π × R c o m p × C c o m p

    Frequncy for the high frequency pole:

    Equation 5. F V _ p o l e ,   H F   =   1 2 × π × R c o m p × C h f , c o m p
  3. Average Current Control Loop: For applications demanding precise output current regulation such as LED applications, the LM51770's average current control loop offers a more appropriate solution. This loop senses the DC output current directly via the current sense resistor RISNS, placed after the output filter. The sensed average current value is used to directly control the COMP voltage to regulate the inductor current, which modulates the PWM duty cycle to tightly regulate the output current, as illustrated in Figure 4-2. This closed-loop approach makes the average current control loop particularly well-suited for high-accuracy LED drive and constant-current applications. Whereas, the small-signal stability of the ILIM loop is governed by the current limit loop gain, denoted as T i l i m ( s ) as given by the equation 6.
    Equation 6. T i l i m ( s )   =   G v c ,   i s n s ( s )   ×   R s n s ,   i l i m ×   G i l i m ( s )
    Where:

    A. R s n s ,   i l i m :

    Where:

    is the ILIM current sense resistor (labeled by R6 in the EVM)

    B. Control-to-Sense Plant Transfer Function: G v c ,   i s n s ( s ) ​

    The plant component represents the relationship between the control signal (Duty Cycle) and the resulting voltage across the current sense resistor. It incorporates the modulator dynamics and the power stage inductor current response.

    Equation 7. G v c ,   i s n s ( s )   =   F m ( s )   ×   G d ,   i s ( s ) 1 + F m ( s )   ×   K C S   ×   H e ( s )   ×   G d ,   i L ( s )

    Where:

    • Equation 8. T P K ( s )   =   F m ( s )   ×   F C S   ×   H e ( s )   ×   G d ,   i L ( s )
      is internal peak-current sensing gain in (V/A).
    • Equation 9. G d , i L ( s )   =   i ^ L s d ^ s is the duty cycle to inductor current transfer function
    • Equation 10. G d , i s ( s )   =   i ^ S N S s d ^ s
      is the duty cycle to average current sense transfer function
    • Internal peak-current sensing gain ( K C S ): convertes the small signal inductor current into the internal peak-current sense voltage.
      Equation 11. K C S =   v ^ C S A i L ^
    • He​(s) is sampling correction: Represents the sampled-data effect of constant frequency peak current mode control. The peak-current comparator samples and terminates the switching cycle once per switching period, so the inner current loop is not purely continuous-time.

      Equation 12. H e ( s )   =   1 - s 2 f s + s 2 ( πf s ) 2

    • Fm​(s) is modulator gain: The gain of the PWM modulator, which relates the control voltage to the duty cycle D. For a Buck-Boost converter, this is approximately:

      Equation 13. F m   =   1 T s × ( S n + S e ) = f s S n + S e

      • Equation 14. S n
        ​ is the natural sensed-current ramp slope in V/s
      • Equation 15. S e ​ is the slope-compensation ramp in V/s
      • Equation 16. F s is the switching frequency.

    C. Current Limit Compensator: G i l i m ( s )

    The compensation network Gilim​(s) is a high-order compensator designed to provide sufficient phase margin at the current loop crossover frequency and to reject high-frequency noise from the current sensing path. Based on the implemented control architecture, the transfer function is defined as:

    Equation 17. G i l i m ( s )   =   G m ,   i l i m   *   1   +   s ( R c ,   i l i m   C c , i l i m ) s C c ,   i l i m × ( 1 + s R c ,   i l i m   C h f ,   i l i m )

    Where:

    • Equation 18. G m ,   i l i m
      is the DC gain of the ILIM current error amplifier.
    • Equation 19. R c ,   i l i m is the resistor in the compensation network, determines the location of the zero and HF pole (labeled by R17 in the EVM)
    • Equation 20. C c ,   i l i m
      is the capacitor in the compensation network, determines the integration strength and zero location (labeled by C18 in the EVM).
    • Equation 21. C h f ,   i l i m
      is the capacitor in the compensation network, creates the high-frequency roll-off pole (labeled by C33 in the EVM).

    The equations for the poles and zero for the type II compensation for the average current control loop is given by the equation 12-14.

    Equation 22. F I L I M _ p o l e ,   o r i g i n   =   0

    Frequency for the Pole on origin:

    Frequency for the Zero:Frequency for the high frequency pole:

    Equation 23. F I L I M _ z e r o   =   1 2 × π × R c , i l i m × C c , i l i m
    Equation 24. F I L I M _ p o l e ,   H F   =   1 2 × π × R c , i l i m × C h f , i l i m
 Control Loops for LM51770
                    Device Figure 4-2 Control Loops for LM51770 Device