SLASEX7C June 2021 – January 2026 TAS5828M
PRODUCTION DATA
Some of host processor Halt the I2S clock when there is no audio playing. When Clock halt, the device puts all channels into the Hi-Z state and reports Clock Error in Register 113 (Register Address 0x71). After audio clocks recovery, the device automatically returns to the previous state.