SLAZ769 December   2025 MSPM33C321A

 

  1.   1
  2.   Abstract
  3. 1Functional Advisories
  4. 2Preprogrammed Software Advisories
  5. 3Debug Only Advisories
  6. 4Fixed by Compiler Advisories
  7. 5Device Nomenclature
    1. 5.1 Device Symbolization and Revision Identification
  8. 6Advisory Descriptions
    1. 6.1 AES_ERR_01
    2. 6.2 GPIO_ERR_05
    3. 6.3 GPIO_ERR_06
    4. 6.4 KEYSTORE_ERR_01
    5. 6.5 SYSCTL_ERR_01
    6. 6.6 SYSPLL_ERR_01
    7. 6.7 TIMER_ERR_04
    8. 6.8 TIMER_ERR_06
    9. 6.9 TIMER_ERR_07
  9. 7Trademarks
  10. 8Revision History

TIMER_ERR_06

TIMG Module

Category

Functional

Function

Writing 0 to CLKEN bit does not disable counter

Description

Writing 0 to the Counter Clock Control Register(CCLKCTL) Clock Enable bit(CLKEN) does not stop the timer.

Workaround

Stop the timer by writing 0 to the Counter Control(CTRCTL) Enable(EN) bit.