SLLK033 January   2025 THVD9491-SEP

 

  1.   1
  2.   Abstract
  3.   Trademarks
  4. 1Device Information
    1. 1.1 Device Details
  5. 2Total Dose Test Setup
    1. 2.1 Test Overview
    2. 2.2 Test Description and Facilities
    3. 2.3 Test Setup Details
      1. 2.3.1 Bias Diagram
    4. 2.4 Test Configuration and Condition
  6. 3TID Characterization Test Results
    1. 3.1 TID Characterization Summary Results
    2. 3.2 Specification Compliance Matrix
  7. 4Reference Documents
  8. 5Appendix A: HDR TID Report Data

Device Details

Table 1-1 lists the device information used for TID HDR characterization and qualification.

Table 1-1 Device and Exposure Details
TID HDR Details: up to 30krad(Si)
TI Device NumberTHVD9491-SEP
Package14-pin D (SOIC)
TechnologyLBC9
Die Lot Number

4083962

A/T Lot Number and Date Code

4566034ML4 / 48C78HK

Quantity Tested

20 irradiated devices + 3 control

Lot Accept or RejectDevices passed 30krad(Si)
HDR Radiation FacilityTexas Instruments CLAB in Dallas, Texas
HDR Dose Level10krad(Si), 20krad(Si), 30krad(Si)
HDR Dose Rate

168.26rad(Si)/s ionizing radiation

Effective Dose Rate with 72 hour Anneal

115.74mrad(Si)/s ionizing radiation

HDR Radiation SourceGammacell 220 Excel (GC-220E) Co-60
Irradiation TemperatureAmbient, room temperature